Proline t-mass 65 PROFIBUS DP
Safety instructions
5
1
Safety instructions
1.1
Designated use
The measuring device described in these Operating Instructions is to be used only for measuring the
mass flow rate of gases. At the same time, the system also measures gas temperature and calculates
other variables such as corrected volume flow. The measuring device can be configured to measure
pure gases or gas mixtures.
Examples:
• Compressed air
• Oxygen
• Nitrogen
• Carbon Dioxide
• Argon, etc.
The use with saturated and wet/dirty gases should be treated with caution (contact your
Hauser representative). The use with unstable gases should be avoided.
Resulting from incorrect use or from use other than that designated, the operational safety of the
measuring devices can be jeopardized. The manufacturer accepts no liability for damages being
produced from this.
1.2
Installation, commissioning and operation
Note the following points:
• Installation, connection to the electricity supply, commissioning and maintenance of the device
must be carried out by trained, qualified specialists authorised to perform such work by the
facility's owner operator.
The specialist must have read and understood these Operating Instructions and must follow the
instructions they contain.
• The device must be operated by persons authorised and trained by the facility's owner-operator.
Strict compliance with the instructions in the Operating Instruction is mandatory.
• Hauser is willing to assist in clarifying the chemical resistance properties of parts wetted
by special fluids, including fluids used for cleaning. However small changes in temperature,
concentration or the degree of contamination in the process can result in changes of the chemical
resistance properties. Therefore, Hauser can not guarantee or accept liability for the
chemical resistance properties of the fluid wetted materials in a specific application. The user is
responsible for the choice of fluid wetted materials in regards to their in-process resistance to
corrosion.
• If carrying out welding work on the piping, the welding unit should not be grounded by means
of the measuring device.
• The installer must ensure that the measuring system is correctly wired in accordance with the
wiring diagrams. The transmitter must be earthed unless special protection measures have been
taken e.g. galvanically isolated power supply SELV or PELV! (SELV = Safe Extra Low Voltage;
PELV = Protective Extra Low Voltage)
• Invariably, local regulations governing the opening and repair of electrical devices apply.