Proline t-mass 65 PROFIBUS DP
Installation
13
3.2.3
Orientation
The device can generally be installed in any position in the piping. In the case of wet/dirty gases,
upward flow is prefered in vertical pipes to minimise condensation/contamination. Where free
condensation can occur (e.g. Biogas) the sensor should be orientated to prevent water collecting on
or around the transducer.
Make sure that the direction arrow on the sensor matches the direction of flow (direction of fluid
flow through the pipe).
Flanged version
Insertion version
Vertical orientation
a0005107
compact
ÃÃ
remote
ÃÃ
a0005110
compact
Ã
remote
ÃÃ
Horizontal orientation:
a0005108
compact
ÃÃ
remote
ÃÃ
a0005111
compact
ÃÃ
remote
ÃÃ
Horizontal orientation:
a0005109
compact
✘
remote
✘
a0005112
compact
✘
remote
✘
ÃÃ
= Recommended orientation
Ã
= Orientation recommended in certain situations
✘
= Not recommended