Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
177
Issue Number: 5 www.controltechniques.com
11.11 Menu 11: General drive set-up
* Modes 1 and 2 are not user saved, Modes 0, 3 and 4 are user saved
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
RFC
OL
RFC
11.01
Parameter 0.11 set up
Pr
1.00
to Pr
50.99
Pr
5.01
RW Uni
PT US
11.02
Parameter 0.12 set up
Pr
4.01
RW Uni
PT US
11.03
Parameter 0.13 set up
Pr
4.20
RW Uni
PT US
11.04
Parameter 0.14 set up
Pr
2.04
RW Uni
PT US
11.05
Parameter 0.15 set up
Pr
6.53
RW Uni
PT US
11.06
Parameter 0.16 set up
Pr
6.54
RW Uni
PT US
11.07
Parameter 0.17 set up
Pr
0.00
Pr
4.12
RW Uni
PT US
11.08
Parameter 0.18 set up
Pr
5.40
RW Uni
PT US
11.09
Parameter 0.19 set up
Pr
7.11
RW Uni
PT US
11.10
Parameter 0.20 set up
Pr
7.14
RW Uni
PT US
11.11
Parameter 0.21 set up
Pr
7.15
RW Uni
PT US
11.12
Parameter 0.22 set up
Pr
6.16
RW Uni
PT US
11.13
Parameter 0.23 set up
Pr
6.17
RW Uni
PT US
11.14
Parameter 0.24 set up
Pr
6.19
RW Uni
PT US
11.15
Parameter 0.25 set up
Pr
6.20
RW Uni
PT US
11.16
Parameter 0.26 set up
Pr
4.27
RW Uni
PT US
11.17
Parameter 0.27 set up
Pr
4.28
RW Uni
PT US
11.18
Parameter 0.28 set up
Pr
4.29
RW Uni
PT US
11.19
Parameter 0.29 set up
Pr
11.36
RW Uni
PT US
11.20
Parameter 0.30 set up
Pr
11.42
RW Uni
PT US
11.21
Parameter scaling
0.000 to 9.999
1.000
RW Uni
US
11.22
Parameter displayed at power-up
Pr
0.00
to
00.59
Pr
0.10
RW Uni
PT US
11.23
PC comms address
{
0.37
}
0 to 247
1
RW Uni
US
11.24
PC comms mode
{
0.35
}
AnSI (0), rtU (1), Lcd (2)
rtU (1)
RW Txt
PT US
11.25
Baud rate
{
0.36
}
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7),
57600 (8)*, 115200 (9)* *Modbus RTU only
19200 (6)
RW Txt
US
11.26
Minimum comms transmit delay
0 to 250ms
2
RW Uni
US
11.28
Drive derivative
0 to 16
RO Uni
NC PT
11.29
Software version
{
0.50
}
1.00 to 99.99
RO Uni
NC PT
11.30
User security code
{
0.34
}
0 to 999
0
RW Uni
NC PT PS
11.31
User drive mode
{
0.48
}
OPEn LP (1), rfc (2),
OPEn LP (1)
rfc (2)
RW Txt
NC PT
11.32
Drive current scaling
{
0.32
}
0.00 to 9999.99A
RO Uni
NC PT
11.33
Drive voltage rating
{
0.31
}
200 (0), 400 (1), 575 (2), 690 (3)
RO Txt
NC PT
11.34
Software sub-version
0 to 99
RO Uni
NC PT
11.35
Number of modules
0 to 10
0
RW Uni
PT US
11.36
SMARTCARD parameter
data previously loaded
{
0.29
}
0 to 999
0
RO Uni
NC PT US
11.37
SMARTCARD data number
0 to 1003
0
RW Uni
NC
11.38
SMARTCARD data type / mode
0 to 18
RO Txt
NC PT
11.39
SMARTCARD data version
0 to 9,999
0
RW Uni
NC
11.40
SMARTCARD data checksum
0 to 65,335
RO Uni
NC PT
11.41
Status mode timeout
0 to 250s
240
RW Uni
US
11.42
Parameter cloning
{
0.30
}
nonE (0), rEAd (1), Prog (2), AutO (3),
boot (4)
nonE (0)
RW Txt
NC
*
11.43
Load defaults
nonE (0), Eur (1), USA (2)
nonE (0)
RW Txt
NC
11.44
Security status
{
0.49
}
L1 (0), L2 (1), Loc (2)
RW Txt
PT US
11.45
Select motor 2 parameters
OFF (0) or On (1)
OFF (0)
RW Bit
US
11.46
Defaults previously loaded
0 to 2000
RO Uni
NC PT US
11.47
Drive Onboard PLC program enable
Halt program (0)
Run program: out of range = clip (1)
Run program: out of range = trip (2)
Run program: out of range = trip (2)
RW Uni
US
11.48
Drive Onboard PLC program status
-128 to +127
RO
Bi
NC PT
11.49
Drive Onboard PLC programming
events
0 to 65,535
RO Uni
NC PT PS
11.50
Drive Onboard PLC program average
scan time
0 to 65,535 ms
RO Uni
NC PT
11.51
Drive Onboard PLC program first run
OFF (0) or On (1)
RO Bit
NC PT
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save
Содержание Affinity
Страница 274: ...0474 0000 05 ...