Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
180
Affinity User Guide
www.controltechniques.com Issue Number: 5
Figure 11-17 Open-loop brake function
The brake control functions are provided to allow well co-ordinated operation of an external brake with the drive. While both hardware and
software are designed to high standards of quality and robustness, they are not intended for use as safety functions, i.e. where a fault or
failure would result in a risk of injury. In any application where the incorrect operation of the brake release mechanism could result in injury,
independent protection devices of proven integrity must also be incorporated.
WARNING
The control terminal relay can be selected as an output to release a brake. If a drive is set up in this manner and a drive replacement takes
place, prior to programming the drive on initial power up, the brake may be released.
When drive terminals are programmed to non default settings the result of incorrect or delayed programming must be considered. The use of
a Smartcard in boot mode can ensure drive parameters are immediately programmed to avoid this situation.
WARNING
4.01
Current
magnitude
Upper current
threshold
Lower current
threshold
12.42
12.43
+
_
5.01
Output
frequency
Brake release
frequency
Brake apply
frequency
12.44
12.45
+
_
+
_
1.11
Reference
on
LAT
10.02
Drive
active
Post-brake
release
delay
12.47
Pre-brake
release
delay
12.46
12.40
Brake
release
Ramp
hold
2.03
Brake
controller
enable
12.41
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
i
o
r
LAT
input
reset
output
If the reset input is 1, the output is 0.
If the reset input is 0, the output
latches at 1 if the input is 1.
i
r
o
2
3
8.12
8.17
8.22
8.27
8.32
T25 digital
I/O 2 invert
Relay source
invert
T25 digital I/O 2
source / destination
Relay source
T25 digital I/O 12
output select
Содержание Affinity