4.11.5 Compliance with generic emission standards
The following information applies to frame sizes 1 to 5.
Size 6 upwards does not comply with the requirements of the generic
standards for radiated emission.
Size 6 complies with the requirements for conducted emission.
Use the recommended filter and shielded motor cable. Observe the
layout rules given in Figure 4-24. Ensure the AC supply and ground
cables are at least 100mm from the power module and motor cable.
Figure 4-24 Supply and ground cable clearance (size 1 to 3)
Figure 4-25 Supply and ground cable clearance (size 4 to 6)
≥
100mm
(4in)
≥
100mm
(4in)
Do not modify
the filter wires
100mm (4in)
100mm
(4in)
100mm (4in)