Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
106
Affinity User Guide
www.controltechniques.com Issue Number: 5
6.2 Full descriptions
6.2.1 Parameter x.00
Pr
x.00
is available in all menus and has the following functions.
information of these functions.
** These functions do not require a drive reset to become active. All
other functions require a drive reset to initiate the function.
6.2.2 Speed limits
(When the drive is jogging, [
0.01
] has no effect.)
Open-loop
Set Pr
0.01
at the required minimum output frequency of the drive for
both directions of rotation. The drive speed reference is scaled between
Pr
0.01
and Pr
0.02
. [
0.01
] is a nominal value; slip compensation may
cause the actual frequency to be higher.
RFC
Set Pr
0.01
at the required minimum motor speed for both directions of
rotation. The drive speed reference is scaled between Pr
0.01
and Pr
0.02
.
(The drive has additional over-speed protection.)
Open-loop
Set Pr
0.02
at the required maximum output frequency for both
directions of rotation. The drive speed reference is scaled between
Pr
0.01
and Pr
0.02
. [
0.02
] is a nominal value; slip compensation may
cause the actual frequency to be higher.
RFC
Set Pr
0.02
at the required maximum motor speed for both directions of
rotation. The drive speed reference is scaled between Pr
0.01
and Pr
0.02
.
For operating at high speeds see section 8.5
6.2.3 Ramps, speed reference selection, current
limit
Set Pr
0.03
at the required rate of acceleration.
Note that larger values produce lower acceleration. The rate applies in
both directions of rotation.
Set Pr
0.04
at the required rate of deceleration.
Note that larger values produce lower deceleration. The rate applies in
both directions of rotation.
Use Pr
0.05
to select the required frequency/speed reference as follows:
Setting Pr
0.05
to 1, 2 or 3 will re-configure T28 and T29. Refer to
Pr
8.39
to disable this function. See section 11.21.1
for further details.
0.00 {x.00}
Parameter zero
RW
Uni
Ú
0 to 32,767
Ö
0
Value
Action
1000
Save parameters when under voltage is not active (Pr
10.16
= 0) and low voltage DC supply is not active (Pr
6.44
= 0).
1001
Save parameters under all conditions
1070
Reset all Solutions Modules
1233
Load standard defaults
1244
Load US defaults
1253
Change drive mode with standard defaults
1254
Change drive mode with US defaults
1255
Change drive mode with standard defaults (excluding menus
15 to 20)
1256
Change drive mode with US defaults (excluding menus 15 to
20)
2001*
Transfer drive parameters as difference from default to a
bootable SMARTCARD block in data block number 001
3yyy*
Transfer drive EEPROM data to a SMARTCARD block
number yyy
4yyy*
Transfer drive data as difference from defaults to
SMARTCARD block number yyy
5yyy*
Transfer drive ladder program to SMARTCARD block
number yyy
6yyy*
Transfer SMARTCARD data block number yyy to the drive
7yyy*
Erase SMARTCARD data block number yyy
8yyy*
Compare drive parameters with SMARTCARD data block
number yyy
9555*
Clear SMARTCARD warning suppression flag
9666*
Set SMARTCARD warning suppression card
9777*
Clear SMARTCARD read-only flag
9888*
Set SMARTCARD read-only flag
9999*
Erase SMARTCARD data block 1 to 499
12000** Display non-default values only
12001** Display destination parameters only
0.01 {1.07}
Minimum reference clamp
RW
Bi
PT
US
OL
Ú
±3,000.0Hz
Ö
0.0
RFC
Ú
±
SPEED_LIMIT_MAX Hz/rpm
Ö
0.0
0.02 {1.06}
Maximum reference clamp
RW
Uni
US
OL
Ú
0 to 3,000.0Hz
Ö
EUR> 50.0
USA> 60.0
RFC
Ú
SPEED_LIMIT_MAX Hz/rpm
Ö
EUR> 1,500.0
USA> 1,800.0
0.03 {2.11}
Acceleration rate
RW
Uni
US
OL
Ú
0.0 to 3,200.0 s/100Hz
Ö
EUR> 40.0
USA> 33.3
RFC
Ú
0.000 to 3,200.000
s/1,000rpm
Ö
EUR> 13.333
USA> 11.111
0.04 {2.21}
Deceleration rate
RW
Uni
US
OL
Ú
0.0 to 3,200.0 s/100Hz
Ö
EUR> 40.0
USA> 33.3
RFC
Ú
0.000 to 3,200.000
s/1,000rpm
Ö
EUR> 13.333
USA> 11.111
0.05 {1.14}
Reference selector
RW
Txt
NC
US
Ú
0 to 5
Ö
A1.A2 (0)
Setting
A1.A2
0
Analog input 1 OR analog input 2 selectable by digital
input, terminal 28
A1.Pr
1
Analog input 1 OR preset frequency/speed selectable
by digital input, terminal 28 and 29
A2.Pr
2
Analog input 2 OR preset frequency/speed selectable
by digital input, terminal 28 and 29
Pr
3
Pre-set frequency/speed
PAd
4
Keypad reference
Prc
5
Precision reference
Содержание Affinity
Страница 274: ...0474 0000 05 ...