Table 12-41 Size 4 (690V) emission compliance
Table 12-42 Size 5 (400V) emission compliance
Table 12-43 Size 5 (690V) emission compliance
Table 12-44 Size 6 (400V only) emission compliance
*Refer to section 12.1.20
Table 12-45 Size 6 (690V only) emission compliance
*Refer to section 12.1.20
Key
(shown in decreasing order of permitted emission level):
E2R
EN 61800-3:2004 second environment, restricted distribution
(Additional measures may be required to prevent interference)
E2U
EN 61800-3:2004 second environment, unrestricted distribution
I
Industrial generic standard EN 61000-6-4:2007
EN 61800-3:2004 first environment restricted distribution (The
following caution is required by EN 61800-3:2004)
R
Residential generic standard EN 61000-6-3:2007
EN 61800-3:2004 first environment unrestricted distribution
EN 61800-3:2004 defines the following:
•
The first environment is one that includes residential premises. It
also includes establishments directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for residential purposes.
•
The second environment is one that includes all establishments
other than those directly connected to a low-voltage power supply
network which supplies buildings used for residential purposes.
•
Restricted distribution is defined as a mode of sales distribution in
which the manufacturer restricts the supply of equipment to
suppliers, customers or users who separately or jointly have
technical competence in the EMC requirements of the application of
drives.
12.2 Optional external EMC filters
Table 12-46 EMC filter cross reference
Table 12-47 IP54 EMC filter cross reference
Motor cable length
(m)
Switching frequency (kHz)
3
4
6
8
Using internal filter:
Any
E2R
Using external filter:
0 to 25
I
25 to 50
I
E2U
50 to 75
I
E2U
75 to 100
I
E2U
Motor cable
length (m)
Switching frequency (kHz)
3
4
6
8
Using internal filter:
100
E2U
Using external filter:
0 to 100
I
Motor cable
length (m)
Switching frequency (kHz)
3
4
6
8
Using internal filter:
100
E2R
Using external filter:
0 to 25
I
0 to 100
I
Do not use
Motor cable
length (m)
Switching frequency (kHz)
3
4
6
Using internal filter:
0 to 100
E2U
100 to max*
E2R
Using external filter:
0 to 100
I
Motor cable
length (m)
Switching frequency (kHz)
3
4
6
Using internal filter:
0 to 100
E2U
100 to max*
E2R
Using external filter:
0 to 25
I
0 to 100
I
Do not use
This is a product of the restricted distribution class according
to IEC 61800-3. In a residential environment this product may
cause radio interference in which case the user may be
required to take adequate measures.
Drive
Schaffner
Epcos
CT part no.
CT part no.
BA1201 to BA1202
4200-6118
4200-6121
BA1203 to BA1204
4200-6119
4200-6120
BA2201 to BA2203
4200-6210
4200-6211
BA3201 to BA3202
4200-6307
4200-6306
BA4201 to BA4203
4200-6406
4200-6405
BA5201 to BA5202
4200-6503
4200-6501
BA1401 to BA1404
4200-6118
4200-6121
BA1405 to BA1406
4200-6119
4200-6120
BA2401 to BA2403
4200-6210
4200-6211
BA3401 to BA3403
4200-6305
4200-6306
BA4401 to BA4403
4200-6406
4200-6405
BA5401 to BA5402
4200-6503
4200-6501
BA6401 to BA6402
4200-6603
4200-6601
BA3501 to BA3507
4200-6309
4200-6308
BA4601 to BA4606
4200-6408
4200-6407
BA5601 to BA5602
4200-6504
4200-6502
BA6601 to BA6602
4200-6604
4200-6602
Drive
CT Part number
BA1201 to BA1202
4200-6125
BA1203 to BA1204
4200-6124
BA1401 to BA1404
4200-6125
BA1405 to BA1406
4200-6124
BA2201 to BA2203
4200-6218
BA2401 to BA2403
4200-6218
BA3201 to BA3202
4200-6319
BA3401 to BA3403
4200-6318
BA3501 to BA3502
4200-6320