Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
252
Affinity User Guide
www.controltechniques.com Issue Number: 5
C.rtg
SMARTCARD trip: The voltage and/or current rating of the source and destination drives are different
186
Drive rating dependent parameters (parameters with the RA coding) are likely to have different values and ranges with drives of
different voltage and current ratings. Parameters with this attribute will not be transferred to the destination drive by SMARTCARDs
when the rating of the destination drive is different from the source drive and the file is a parameter file. Drive rating dependent
parameters will be transferred if only the current rating is different and the file is a differences from default type file.
Press the red
reset button
Drive rating parameters are:
The above parameters will be set to their default values.
C.TyP
SMARTCARD trip: SMARTCARD parameter set not compatible with drive
187
Press the reset button
Ensure destination drive type is the same as the source parameter file drive type
dESt
Two or more parameters are writing to the same destination parameter
199
Set Pr
xx.00
= 12001 check all visible parameters in the menus for duplication
EEF
EEPROM data corrupted - Drive mode becomes open loop and serial comms will timeout with remote keypad on the drive
RS485 comms port.
31
This trip can only be cleared by loading default parameters and saving parameters
Et
External trip from input on terminal 31
6
Check terminal 31 signal
Check value of Pr
10.32
Enter 12001 in Pr
xx.00
and check for parameter controlling Pr
10.32
Ensure Pr
10.32
or Pr
10.38
(=6) are not being controlled by serial comms
HF01
Data processing error: CPU address error
Hardware fault - return drive to supplier
HF02
Data processing error: DMAC address error
Hardware fault - return drive to supplier
HF03
Data processing error: Illegal instruction
Hardware fault - return drive to supplier
HF04
Data processing error: Illegal slot instruction
Hardware fault - return drive to supplier
HF05
Data processing error: Undefined exception
Hardware fault - return drive to supplier
HF06
Data processing error: Reserved exception
Hardware fault - return drive to supplier
HF07
Data processing error: Watchdog failure
Hardware fault - return drive to supplier
HF08
Data processing error: Level 4 crash
Hardware fault - return drive to supplier
Trip
Diagnosis
Parameter
Function
2.08
Standard ramp voltage
4.05
/
6
/
7
,
21.27/8/9
Current limits
4.24
User current maximum scaling
5.07
,
21.07
Motor rated current
5.09
,
21.09
Motor rated voltage
5.10
,
21.10
Rated power factor
5.17
,
21.12
Stator resistance
5.18
Switching frequency
5.23
,
21.13
Voltage offset
5.24
,
21.14
Transient inductance
5.25
,
21.24
Stator inductance
6.06
DC injection braking current
6.48
Line power supply loss ride through detection level
Содержание Affinity
Страница 274: ...0474 0000 05 ...