SM-I/O Lite parameters
*See trip SLX.Er,
Automation (I/O Expansion) module category
Parameter
Range(
Ú
)
Default(
Ö
)
Type
SM-I/O
Lite Timer
x.01
Solutions Module ID
0 to 599
SM-I/O Lite: 207
RO Uni
PT US
9
9
x.02
Solutions Module software version
0.00 to 99.99
RO Uni
NC PT
9
9
x.03
Current loop loss indicator
OFF (0) or On (1)
RO Bit
NC PT
9
9
x.04
T5 digital input 1 state
RO Bit
NC PT
9
9
x.05
T6 digital input 2 state
RO Bit
NC PT
9
9
x.06
T7 digital input 3 state
RO Bit
NC PT
9
9
x.07
Relay 1 state
RO Bit
NC PT
9
9
x.14
T5 digital input 1 invert
OFF (0)
RW Bit
US
9
9
x.15
T6 digital input 2 invert
RW Bit
US
9
9
x.16
T7 digital input 3 invert
RW Bit
US
9
9
x.17
Relay 1 invert
RW Bit
US
9
9
x.20
Digital I/O read word
0 to 255
RO Uni
NC PT
9
9
x.24
T5 digital input 1 destination
Pr
0.00
to Pr
50.99
Pr
0.00
RW Uni DE
PT US
9
9
x.25
T6 digital input 2 destination
RW Uni DE
PT US
9
9
x.26
T7 digital input 3 destination
RW Uni DE
PT US
9
9
x.27
Relay 1 source
RW Uni
PT US
9
9
x.38
Analog input 1 mode
0-20 (0), 20-0 (1), 4-20.tr (2),
20-4.tr (3), 4-20 (4), 20-4 (5),
VOLt(6)
0-20 (0)
RW Txt
US
9
9
x.39
Analog output mode
0-20 (0), 20-0 (1), 4-20 (2), 20-4 (3),
VOLt (4)
0-20 (0)
RW Txt
US
9
9
x.40
Analog input 1
±100.0%
RO Bi
NC PT
9
9
x.41
Analog input 1 scaling
0 to 4.000
1.000
RW Uni
US
9
9
x.42
Analog input 1 invert
OFF (0) or On (1)
OFF (0)
RW Bit
US
9
9
x.43
Analog input 1 destination
Pr
0.00
to Pr
50.99
Pr
0.00
RW Uni DE
PT US
9
9
x.48
Analog output 1 source
RW Uni
PT US
9
9
x.49
Analog output 1 scaling
0.000 to 4.000
1.000
RW Uni
US
9
9
x.50
Solutions Module error status*
0 to 255
RO Uni
NC PT
9
9
x.51
Solutions Module software sub-version
0 to 99
RO Uni
NC PT
9
9
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save