Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
181
Issue Number: 5 www.controltechniques.com
Figure 11-18 Open-loop brake sequence
1
2
3
4
6
5
Pr
Output
frequency
5.01
Pr
Reference
on
1.11
Pr
Brake release
12.40
Pr
Ramp hold
2.03
Pr
Drive
active
10.02
Pr
Current magnitude
4.01
1. Wait for upper current threshold and brake release frequency
2. Pre-brake release delay
3. Post-brake release delay
4. Wait for brake apply frequency
5. Wait for zero frequency
6. 1s delay as phase 2 of stopping sequence (Pr
=1,2 or 3)
6.01
Pr
Brake release frequency
12.44
Pr
Brake apply frequency
12.45
Pr
12.46
Pr
12.47
Pr
Upper current threshold
12.42
Содержание Affinity