5 Implementation of EtherNet/IP
5.2 Classes and instances of the EtherNet/IP-gateway
62
XI/ON: XNE-GWBR-2ETH-IP
09/2011 MN05002007Z-EN
www.eaton.com
26
Path Size Invalid
The size of the path which was sent with the Service
Request is either not large enough to allow the Request to
be routed to an object or too much routing data was
included.
27
Unexpected attribute
in list
An attempt was made to set an attribute that is not able to
be set at this time.
28
Invalid Member ID
The Member ID specified in the request does not exist in the
specified Class/Instance/Attribute
29
Member not settable A request to modify a non-modifiable member was received
2A
Group 2 only server
general failure
This error code may only be reported by Group 2 Only
servers with 4K or less code space and only in place of
Service not supported, Attribute not supported and Attribute
not settable.
2B to
CF
Reserved by CIP for future extensions
D0 to
FF
Reserved for Object
Class and service
errors
This range of error codes is to be used to indicate Object
Class specific errors. Use of this range should only be
performed when none of the Error Codes presented in this
table accurately reflect the error that was encountered.
Table 18:
General status
codes according
to CIP spec.
Status
code
(hex)
Status name
Description
Содержание XN-GW Series
Страница 1: ...09 2011 MN05002007Z EN User Manual XI ON XNE GWBR 2ETH IP Gateway...
Страница 8: ...Table of contents 8 XI ON XNE GWBR 2ETH IP 09 2011 MN05002007Z EN www eaton com 10 Index 205...
Страница 12: ...1 About this manual 1 3 Overview 12 XI ON XNE GWBR 2ETH IP 09 2011 MN05002007Z EN www eaton com...
Страница 28: ...3 EtherNet IP 3 1 System description 28 XI ON XNE GWBR 2ETH IP 09 2011 MN05002007Z EN www eaton com...
Страница 184: ...7 Guidelines for station planning 7 7 Firmware download 184 XI ON XNE GWBR 2ETH IP 09 2011 MN05002007Z EN www eaton com...
Страница 204: ...9 Appendix 9 3 Glossary 204 XI ON XNE GWBR 2ETH IP 09 2011 MN05002007Z EN www eaton com...