
Machine head
Service Instructions 911-211 - 02.0 - 10/2016
42
Disturbances caused by an incorrect setting of the needle guide
• Damage to the needle
• Missing stitches
Fig. 29: Setting the needle guide
To set the needle guide:
1.
Loosen the screws (1).
2.
Remove the throat plate (2).
3.
Rotate the machine to position 1 (
4.
Loosen the screw (4).
5.
Move the needle guide (3) as close as possible against the needle.
6.
Tighten the screw (4).
7.
Check this distance using a piece of paper (5).
(1)
- Screws
(2)
- Throat plate
(3)
- Needle guide
(4)
- Screw
(5)
- Paper
⑤
①
② ③
④
Содержание 911-211
Страница 1: ...Service Instructions 911 211...
Страница 6: ...Table of Contents 5 Service Instructions 911 211 02 0 10 2016...
Страница 10: ...About these instructions 9 Service Instructions 911 211 02 0 10 2016...
Страница 90: ...Sewing unit 89 Service Instructions 911 211 02 0 10 2016...
Страница 146: ...Creating programs with DA CAD 5000 145 Service Instructions 911 211 02 0 10 2016...
Страница 158: ...Decommissioning 157 Service Instructions 911 211 02 0 10 2016...
Страница 160: ...Disposal 159 Service Instructions 911 211 02 0 10 2016...
Страница 170: ...Technical data 169 Service Instructions 911 211 02 0 10 2016...
Страница 195: ...Appendix Service Instructions 911 211 02 0 10 2016 194...
Страница 197: ...Appendix Service Instructions 911 211 02 0 10 2016 196 13 3 Pneumatic diagram...
Страница 198: ...Appendix 197 Service Instructions 911 211 02 0 10 2016 13 4 Pneumatic diagram for machines with remaining thread monitor...
Страница 199: ......