Sewing unit
Service Instructions 911-211 - 02.0 - 10/2016
86
5.2.2 Changing the X drive
Fig. 70: Changing the X drive
Disassembling the X drive
To disassemble the drive:
1.
Disconnect both plugs (4).
2.
Loosen all 4 screws (1).
3.
Pull off the motor and flange (3).
Assembling the X drive
To assemble the drive:
1.
Insert a new motor and flange (3) on to the toothed belt (2).
2.
Insert all 4 screws (1) and tighten them loosely.
3.
Tension the toothed belt (2) using the screw (5).
Information
The toothed belt tension is set to the optimum value when the belt oscil-
lates at 384 Hz. Check the oscillation, for instance, using a device made
by Contitech.
4.
Tighten all 4 screws (1).
5.
Connect the plug (4).
(1)
- Screws
(2)
- Toothed belt
(3)
- Motor with flange
(4)
- Plug
(5)
- Screw
④
⑤
①
②
③
Содержание 911-211
Страница 1: ...Service Instructions 911 211...
Страница 6: ...Table of Contents 5 Service Instructions 911 211 02 0 10 2016...
Страница 10: ...About these instructions 9 Service Instructions 911 211 02 0 10 2016...
Страница 90: ...Sewing unit 89 Service Instructions 911 211 02 0 10 2016...
Страница 146: ...Creating programs with DA CAD 5000 145 Service Instructions 911 211 02 0 10 2016...
Страница 158: ...Decommissioning 157 Service Instructions 911 211 02 0 10 2016...
Страница 160: ...Disposal 159 Service Instructions 911 211 02 0 10 2016...
Страница 170: ...Technical data 169 Service Instructions 911 211 02 0 10 2016...
Страница 195: ...Appendix Service Instructions 911 211 02 0 10 2016 194...
Страница 197: ...Appendix Service Instructions 911 211 02 0 10 2016 196 13 3 Pneumatic diagram...
Страница 198: ...Appendix 197 Service Instructions 911 211 02 0 10 2016 13 4 Pneumatic diagram for machines with remaining thread monitor...
Страница 199: ......