ConÞguring the DL600E Unit
3-5
Connecting DL600E Units in a Daisy Chain
You can daisy chain up to
60 DL600E unit
s for centralized network
monitoring and management.
Use an
RS-232
ribbon-type cable with
DE9
connectors (available from
Digital Link).
D
Note:
CTS
(pin
8
)
must
be connected between DL600E
units, but it
must not
be connected to the terminal.
If you are using a cable not provided by Digital Link,
refer to Comm Port pin assignments in Appendix B.
To daisy-chain multiple systems together using a single
RS-232
multidrop cable:
1
Using a ribbon cable with
DE9
connectors, connect the
cableÕs female
DE9
connector to the terminal or modem (if
at a remote site).
2
Connect the cableÕs male
DE9
connectors to the Comm Port on
each
DL600E unit
.