Central management
Collect device health data and set the sample interval
IX14 User Guide
507
report health metrics. This is useful to reduce the bandwidth used to report health metrics.
Even if enabled, all metrics are uploaded once every hour.
To disable:
(config)> monitoring devicehealth only_send_deltas false
(config)>
When disabled, all metrics are uploaded every
Health sample interval
.
6. (Optional) Tuning parameters allow to you configure what data are uploaded to the Digi
Remote Manager. By default, all tuning parameters are enabled.
To view a list of all available tuning parameters, use the
show
command:
(config)> show monitoring devicehealth tuning
all
cellular
rx
bytes
enable true
tx
bytes
enable true
eth
rx
bytes
enable true
tx
bytes
enable true
serial
rx
bytes
enable true
tx
bytes
enable true
cellular
1
rx
bytes
enable true
packets
enable true
...
(config)>
To disable a tuning parameter, set its value to false. For example, to turn off all reporting for
the serial port:
(config)> monitoring devicehealth tuning all serial rx bytes enabled
false
Содержание IX14
Страница 1: ...IX14 User Guide Firmware version 22 2 ...
Страница 45: ...Configuration and management Exit the command line interface IX14 User Guide 45 Type q or quit to exit ...
Страница 515: ...Monitoring This chapter contains the following topics intelliFlow 516 Configure NetFlow Probe 523 IX14 User Guide 515 ...
Страница 756: ...Routing Virtual Router Redundancy Protocol VRRP IX14 User Guide 756 ...
Страница 803: ...Command line interface Command line reference IX14 User Guide 803 Parameters None ...
Страница 812: ...Command line interface Command line reference IX14 User Guide 812 reboot Reboot the system Parameters None ...