Services
System time
IX14 User Guide
406
System time
By default, the IX14 device synchronizes the system time by periodically connecting to the Digi NTP
server,
time.devicecloud.com
. In this mode, the device queries the time server based on following
events and schedule:
n
At boot time.
n
Once a day.
The default configuration has the system time zone set to UTC. No additional configuration is required
for the system time if the default configuration is sufficient. However, you can change the default time
zone and the default NTP server, as well as configuring additional NTP servers. If multiple servers are
configured, a number of time samples are obtained from each of the servers and a subset of the NTP
clock filter and selection algorithms are applied to select the best of these. See
for details about changing the default configuration.
The IX14 device can also be configured to serve as an NTP server, providing NTP services to
downstream devices. See
for more information about NTP server support.
You can also set the local date and time manually, if there is no access to NTP servers. See
for information
Configure the system time
This procedure is optional.
The IX14 device's default system time configuration uses the Digi NTP server,
time.devicecloud.com
,
and has the time zone set to
UTC
. You can change the default NTP server and the default time zone.
You can also set the local date and time without using an upstream NTP server, as well as configuring
additional NTP servers.
Required Configuration Items
n
The time zone for the IX14 device.
n
If t least one upstream NTP server for synchronization.
Additional Configuration Options
n
Additional upstream NTP servers.
WebUI
1. Log into the IX14 WebUI as a user with full Admin access rights.
2. On the menu, click
System
. Under
Configuration
, click
Device Configuration
.
The
Configuration
window is displayed.
Содержание IX14
Страница 1: ...IX14 User Guide Firmware version 22 2 ...
Страница 45: ...Configuration and management Exit the command line interface IX14 User Guide 45 Type q or quit to exit ...
Страница 515: ...Monitoring This chapter contains the following topics intelliFlow 516 Configure NetFlow Probe 523 IX14 User Guide 515 ...
Страница 756: ...Routing Virtual Router Redundancy Protocol VRRP IX14 User Guide 756 ...
Страница 803: ...Command line interface Command line reference IX14 User Guide 803 Parameters None ...
Страница 812: ...Command line interface Command line reference IX14 User Guide 812 reboot Reboot the system Parameters None ...