Services
Location information
IX14 User Guide
381
Command line
1. Log into the IX14 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. At the command line, type
config
to enter configuration mode:
> config
(config)>
3. Add a geofence:
(config)> add service location geofence
name
(config service location geofence
name
)>
where
name
is a name for the geofence. For example:
(config)> add service location geofence test_geofence
(config service location geofence test_geofence)>
The geofence is enabled by default. To disable:
(config service location geofence test_geofence)> enable false
(config service location geofence test_geofence)>
4. Set the amount of time that the geofence should wait between polling for updated location
data:
(config service location geofence test_geofence)> update_interval
value
(config service location geofence test_geofence)>
where
value
is any number of weeks, days, hours, minutes, or seconds, and takes the format
number
{
w|d|h|m|s
}.
For example, to set
update_interval
to ten minutes, enter either
10m
or
600s
:
(config service location geofence test_geofence)> update_interval 600s
(config service location geofence test_geofence)>
The default is
1m
(one minute).
5. Set the boundary type for the geofence:
(config service location geofence test_geofence)> boundary
value
(config service location geofence test_geofence)>
Содержание IX14
Страница 1: ...IX14 User Guide Firmware version 22 2 ...
Страница 45: ...Configuration and management Exit the command line interface IX14 User Guide 45 Type q or quit to exit ...
Страница 515: ...Monitoring This chapter contains the following topics intelliFlow 516 Configure NetFlow Probe 523 IX14 User Guide 515 ...
Страница 756: ...Routing Virtual Router Redundancy Protocol VRRP IX14 User Guide 756 ...
Страница 803: ...Command line interface Command line reference IX14 User Guide 803 Parameters None ...
Страница 812: ...Command line interface Command line reference IX14 User Guide 812 reboot Reboot the system Parameters None ...