Serial port
IX14 User Guide
171
3. Set the type of parity used by the device to which you want to connect:
(config)>path-paramparity
parity
(config)>
Allowed values are:
n
even
n
odd
n
none
The default is
none
.
4. Set the stop bits used by the device to which you want to connect:
(config)>path-paramstopbits
bits
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type
exit
to exit the Admin CLI.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
quit
to disconnect from the device.
Show serial status and statistics
To show the status and statistics for the serial port:
WebUI
1. Log into the IX14 WebUI as a user with Admin access.
2. On the main menu, click
Status
3. Under
Connections
, click
Serial
.
Command line
1. Log into the IX14 command line as a user with Admin access.
Depending on your device configuration, you may be presented with an
Access selection
menu
. Type
admin
to access the Admin CLI.
2. Use the
command:
> show serial
Label
Port
Enable
Mode
Baudrate
--------
-----
------
-----
--------
Serial 1
port1
true
login
115000
>
Содержание IX14
Страница 1: ...IX14 User Guide Firmware version 22 2 ...
Страница 45: ...Configuration and management Exit the command line interface IX14 User Guide 45 Type q or quit to exit ...
Страница 515: ...Monitoring This chapter contains the following topics intelliFlow 516 Configure NetFlow Probe 523 IX14 User Guide 515 ...
Страница 756: ...Routing Virtual Router Redundancy Protocol VRRP IX14 User Guide 756 ...
Страница 803: ...Command line interface Command line reference IX14 User Guide 803 Parameters None ...
Страница 812: ...Command line interface Command line reference IX14 User Guide 812 reboot Reboot the system Parameters None ...