Applications
Configure scripts to run automatically
IX14 User Guide
449
Custom scripts are enabled by default. To disable, click
Enable
to toggle off.
5. (Optional) For
Label
, provide a label for the script.
6. For
Run mode
, select the mode that will be used to run the script. Available options are:
n
On boot
: The script will run once each time the device boots.
l
If
On boot
is selected, select the action that will be taken when the script completes
in
Exit action
. Available options are:
o
None
: Action taken when the script exits.
o
Restart script
: Runs the script repeatedly.
o
Reboot
: The device will reboot when the script completes.
n
Interval
: The script will start running at the specified interval, within 30 seconds after
the configuration change is saved.
l
If
Interval
is selected, in
Interval
, type the interval.
Allowed values are any number of weeks, days, hours, minutes, or seconds, and
take the format
number
{
w|d|h|m|s
}.
For example, to set
Interval
to ten minutes, enter
10m
or
600s
.
l
Click to enable
Run single
to run only a single instance of the script at a time.
If
Run single
is not enabled, a new instance of the script will be started at every
interval, regardless of whether the script is still running from a previous interval.
n
Set time
: Runs the script at a specified time of the day.
l
If
Set Time
is selected, specify the time that the script should run in
Run time
,
using the format
HH
:
MM
.
n
During system maintenance
: The script will run during the system maintenance time
window.
7. For
Commands
, enter the commands that will execute the script.
If the script begins with
#!
, then the script will be invoked in the location specified by the path
for the script command. Otherwise, the default shell will be used (equivalent to
#!/bin/sh
).
8. Script logging options:
a. Click to enable
Log script output
to log the script's output to the system log.
b. Click to enable
Log script errors
to log script errors to the system log.
If neither option is selected, only the script's exit code is written to the system log.
9. For
Maximum memory
, enter the maximum amount of memory available to be used by the
script and its subprocesses, using the format
number
{
b
|
bytes
|
KB
|
k
|
MB
|
MB
|
M
|
GB
|
G
|
TB
|
T
}.
Содержание IX14
Страница 1: ...IX14 User Guide Firmware version 22 2 ...
Страница 45: ...Configuration and management Exit the command line interface IX14 User Guide 45 Type q or quit to exit ...
Страница 515: ...Monitoring This chapter contains the following topics intelliFlow 516 Configure NetFlow Probe 523 IX14 User Guide 515 ...
Страница 756: ...Routing Virtual Router Redundancy Protocol VRRP IX14 User Guide 756 ...
Страница 803: ...Command line interface Command line reference IX14 User Guide 803 Parameters None ...
Страница 812: ...Command line interface Command line reference IX14 User Guide 812 reboot Reboot the system Parameters None ...