1.4. ADDITIONAL INDICATIONS
2011/65/EU (RoHS 2),
European standard on the
restriction of the use of certain harmful substances
(lead, mercury, cadmium, hexavalent chromium,
polybrominated biphenyls, polybrominated diphenyl
ethers) in small and large household appliances,
computer and telecommunications equipment,
consumer electronic devices, lighting fixtures,
electrical and electronic tools, toys, leisure and sports
equipment, medical devices, control and surveillance
instruments, including industrial control instruments,
vending machines and other equipment not included
in the previous categories.
2012/19/EU (WEEE),
European standard on the
recycling of non-disposable products, such as
unclassified municipal waste within the area of the
European Union. When purchasing an equivalent
new unit, return this product to your local supplier or
dispose of it at the collection points designated for this
purpose in order to facilitate its appropriate recycling.
1.5. GENERAL SAFETY WARNINGS
ONLY STAFF THAT ARE DULY QUALIFIED MUST INSTALL
OR CONFIGURE THIS UNIT.
Read this manual carefully before beginning to install the
panel.
MAKE SURE
you have the appropriate tools
Not paying attention to this warning may cause irreversible
damage to the unit, the facility to malfunction or safety risks
for people.
If you have any queries regarding the assembly, installation
or configuration of the control panel, please contact your
normal distributor or customer service before continuing to
install the unit.
The installation must be carried out in accordance with the
applicable standards issued by the competent authority of the
corresponding country. Consult local, national and business
standards
Do not use the panel or its components beyond their
performance specifications
The ambient operating temperature must be within the range
of -5°C to 40°C
The relative humidity must be within the range of 5% and 95%
without condensation
The control panel must always be connected to a protective
earth.
The installation of the system on CAD-250 control panels must
include a method to isolate or disconnect the input voltage
supply. The isolation or disconnection device must be located
close to the system and be clearly labelled. The isolation or
disconnection device must disconnect both the active and the
neutral pole, but without losing continuity to earth.
Consider the incorporation of protection for the inputs against
overvoltages, depending on the type of location and risk
expected.
All signal and interconnection cables must be armoured and
the mesh must only be connected at the points specified by
this manual.
All ducts and the cable protection must be connected to the
protective earth, trying to avoid earth loops and contact with
the cable shield.
The access doors and entry points must be kept closed when
the system is connected in normal operation.
EN
UNE
ISO
Содержание CAD-250
Страница 1: ...ENG INSTALLATION GUIDE ENG ...
Страница 2: ...ENG 2 ...
Страница 3: ...3 ENG ...
Страница 17: ...17 ENG 1 3 6 3 2 4 5 ...
Страница 21: ...21 ENG 1 2 3 5 4 6 7 ...
Страница 81: ...81 ENG ...
Страница 82: ...ENG 82 ...
Страница 83: ...83 ENG ...
Страница 84: ...ENG 84 MI 375 en 2020 c CAD 250_MI_372_en_2019 d ...