4.1.13 14-** Special Functions
Param-
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
14-0* Inverter Switching
14-00
Switching Pattern
ExpressionLimit
All set-ups
TRUE
-
Uint8
14-01
Switching Frequency
ExpressionLimit
All set-ups
TRUE
-
Uint8
14-03
Overmodulation
[1] On
All set-ups
FALSE
-
Uint8
14-04
PWM Random
[0] Off
All set-ups
TRUE
-
Uint8
14-1* Mains On/Off
14-10
Mains Failure
[0] No function
All set-ups
FALSE
-
Uint8
14-11
Mains Voltage at Mains Fault
ExpressionLimit
All set-ups
TRUE
0
Uint16
14-12
Function at Mains Imbalance
[3] Derate
All set-ups
TRUE
-
Uint8
14-16
Kin. Backup Gain
100%
All set-ups
TRUE
0
Uint32
14-2* Reset Functions
14-20
Reset Mode
[10] Automatic
reset x 10
All set-ups
TRUE
-
Uint8
14-21
Automatic Restart Time
10 s
All set-ups
TRUE
0
Uint16
14-22
Operation Mode
[0] Normal
operation
All set-ups
TRUE
-
Uint8
14-23
Typecode Setting
ExpressionLimit
2 set-ups
FALSE
-
Uint16
14-25
Trip Delay at Torque Limit
60 s
All set-ups
TRUE
0
Uint8
14-26
Trip Delay at Inverter Fault
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-28
Production Settings
[0] No action
All set-ups
TRUE
-
Uint8
14-29
Service Code
0 N/A
All set-ups
TRUE
0
Int32
14-3* Current Limit Ctrl.
14-30
Current Lim Ctrl, Proportional Gain
100%
All set-ups
FALSE
0
Uint16
14-31
Current Lim Ctrl, Integration Time
ExpressionLimit
All set-ups
FALSE
-3
Uint16
14-32
Current Lim Ctrl, Filter Time
ExpressionLimit
All set-ups
FALSE
-4
Uint16
14-4* Energy Optimizing
14-40
VT Level
66%
All set-ups
FALSE
0
Uint8
14-41
AEO Minimum Magnetization
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-42
Minimum AEO Frequency
ExpressionLimit
All set-ups
TRUE
0
Uint8
14-43
Motor Cosphi
ExpressionLimit
All set-ups
TRUE
-2
Uint16
14-5* Environment
14-50
RFI Filter
[1] On
1 set-up
FALSE
-
Uint8
14-51
DC Link Compensation
ExpressionLimit
All set-ups
TRUE
-
Uint8
14-52
Fan Control
[0] Auto
All set-ups
TRUE
-
Uint8
14-53
Fan Monitor
[1] Warning
All set-ups
TRUE
-
Uint8
14-55
Output Filter
[0] No Filter
1 set-up
FALSE
-
Uint8
14-56
Capacitance Output Filter
2 uF
1 set-up
FALSE
-7
Uint16
14-57
Inductance Output Filter
7 mH
1 set-up
FALSE
-6
Uint16
14-58
Voltage Gain Filter
100%
All set-ups
TRUE
0
Uint16
14-59
Actual Number of Inverter Units
ExpressionLimit
1 set-up
FALSE
0
Uint8
14-6* Auto Derate
14-60
Function at Over Temperature
[1] Derate
All set-ups
TRUE
-
Uint8
14-61
Function at Inverter Overload
[1] Derate
All set-ups
TRUE
-
Uint8
14-62
Inv. Overload Derate Current
95%
All set-ups
TRUE
0
Uint16
14-8* Options
14-80
Option Supplied by External 24VDC
[0] No
2 set-ups
FALSE
-
Uint8
14-9* Fault Settings
14-90
Fault Level
ExpressionLimit
1 set-up
TRUE
-
Uint8