3.24.11 27-7* Connections
Parameters for configuring relay connections.
27-70 Relay
This parameter is only relevant for a relay wiring configuration.
Use this parameter to set up the function of the option relays.
This parameter is an array. The visibility of options depends on
the MCO option installed in the frequency converter:
•
VLT
®
Extended Cascade Controller MCO 101: Relays 10–
12 are available.
•
VLT
®
Advanced Cascade Controller MCO 102: Relays
13-20 are available.
In any case, the standard relays (Relay 1 and Relay 2), and the
relays in the VLT
®
Relay Option MCB 105 are available.
To set the function of a specific relay, select the relay and then
select the function. If the
option [0] Standard Relay
is selected,
the relay can be used as a general-purpose relay and the
function can be set in
parameter group 5-4* Relays
.
Option:
Function:
[0]
*
Standard Relay
Enable slave
frequency
converter X.
[1]
Drive 2 Enable
[2]
Drive 3 Enable
[3]
Drive 4 Enable
[4]
Drive 5 Enable
[5]
Drive 6 Enable
[6]
Drive 7 Enable
[7]
Drive 8 Enable
[8]
Pump 1 to Drive 1
[9]
Pump 1 to Drive 2
[10]
Pump 1 to Drive 3
[11]
Pump 1 to Drive 4
[12]
Pump 1 to Drive 5
[13]
Pump 1 to Drive 6
[14]
Pump 1 to Drive 7
[15]
Pump 1 to Drive 8
[16]
Pump 2 to Drive 1
[17]
Pump 2 to Drive 2
[18]
Pump 2 to Drive 3
[19]
Pump 2 to Drive 4
[20]
Pump 2 to Drive 5
[21]
Pump 2 to Drive 6
[22]
Pump 2 to Drive 7
[23]
Pump 2 to Drive 8
[24]
Pump 3 to Drive 1
[25]
Pump 3 to Drive 2
[26]
Pump 3 to Drive 3
[27]
Pump 3 to Drive 4
[28]
Pump 3 to Drive 5
[29]
Pump 3 to Drive 6
[30]
Pump 3 to Drive 7
[31]
Pump 3 to Drive 8
27-70 Relay
This parameter is only relevant for a relay wiring configuration.
Use this parameter to set up the function of the option relays.
This parameter is an array. The visibility of options depends on
the MCO option installed in the frequency converter:
•
VLT
®
Extended Cascade Controller MCO 101: Relays 10–
12 are available.
•
VLT
®
Advanced Cascade Controller MCO 102: Relays
13-20 are available.
In any case, the standard relays (Relay 1 and Relay 2), and the
relays in the VLT
®
Relay Option MCB 105 are available.
To set the function of a specific relay, select the relay and then
select the function. If the
option [0] Standard Relay
is selected,
the relay can be used as a general-purpose relay and the
function can be set in
parameter group 5-4* Relays
.
Option:
Function:
[32]
Pump 4 to Drive 1
[33]
Pump 4 to Drive 2
[34]
Pump 4 to Drive 3
[35]
Pump 4 to Drive 4
[36]
Pump 4 to Drive 5
[37]
Pump 4 to Drive 6
[38]
Pump 4 to Drive 7
[39]
Pump 4 to Drive 8
[40]
Pump 5 to Drive 1
[41]
Pump 5 to Drive 2
[42]
Pump 5 to Drive 3
[43]
Pump 5 to Drive 4
[44]
Pump 5 to Drive 5
[45]
Pump 5 to Drive 6
[46]
Pump 5 to Drive 7
[47]
Pump 5 to Drive 8
[48]
Pump 6 to Drive 1
[49]
Pump 6 to Drive 2
[50]
Pump 6 to Drive 3
[51]
Pump 6 to Drive 4
[52]
Pump 6 to Drive 5
[53]
Pump 6 to Drive 6
[54]
Pump 6 to Drive 7
[55]
Pump 6 to Drive 8
[56]
Pump 7 to Drive 1
[57]
Pump 7 to Drive 2
[58]
Pump 7 to Drive 3
[59]
Pump 7 to Drive 4
[60]
Pump 7 to Drive 5
[61]
Pump 7 to Drive 6
[62]
Pump 7 to Drive 7
[63]
Pump 7 to Drive 8
[64]
Pump 8 to Drive 1
[65]
Pump 8 to Drive 2
[66]
Pump 8 to Drive 3
[67]
Pump 8 to Drive 4
[68]
Pump 8 to Drive 5
[69]
Pump 8 to Drive 6
Parameter Description
VLT
®
AQUA Drive FC 202
232
Danfoss A/S © 05/2018 All rights reserved.
MG20OB02
3
3