4.1.5 3-** Reference/Ramps
Param-
eter #
Parameter description
Default value
4 set-up
Change during
operation
Conversion
index
Type
3-0* Reference Limits
3-02
Minimum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-03
Maximum Reference
ExpressionLimit
All set-ups
TRUE
-3
Int32
3-04
Reference Function
[0] Sum
All set-ups
TRUE
-
Uint8
3-1* References
3-10
Preset Reference
0%
All set-ups
TRUE
-2
Int16
3-11
Jog Speed [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
3-13
Reference Site
[0] Linked to Hand/
Auto
All set-ups
TRUE
-
Uint8
3-14
Preset Relative Reference
0%
All set-ups
TRUE
-2
Int32
3-15
Reference 1 Source
[1] Analog Input 53
All set-ups
TRUE
-
Uint8
3-16
Reference 2 Source
[0] No function
All set-ups
TRUE
-
Uint8
3-17
Reference 3 Source
[0] No function
All set-ups
TRUE
-
Uint8
3-19
Jog Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
3-4* Ramp 1
3-41
Ramp 1 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-42
Ramp 1 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-5* Ramp 2
3-51
Ramp 2 Ramp Up Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-52
Ramp 2 Ramp Down Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-8* Other Ramps
3-80
Jog Ramp Time
ExpressionLimit
All set-ups
TRUE
-2
Uint32
3-81
Quick Stop Ramp Time
ExpressionLimit
2 set-ups
TRUE
-2
Uint32
3-84
Initial Ramp Time
0 s
All set-ups
TRUE
-2
Uint16
3-85
Check Valve Ramp Time
0 s
All set-ups
TRUE
-2
Uint16
3-86
Check Valve Ramp End Speed [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
3-87
Check Valve Ramp End Speed [HZ]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
3-88
Final Ramp Time
0 s
All set-ups
TRUE
-2
Uint16
3-9* Digital Pot.Meter
3-90
Step Size
0.10%
All set-ups
TRUE
-2
Uint16
3-91
Ramp Time
1 s
All set-ups
TRUE
-2
Uint32
3-92
Power Restore
[0] Off
All set-ups
TRUE
-
Uint8
3-93
Maximum Limit
100%
All set-ups
TRUE
0
Int16
3-94
Minimum Limit
0%
All set-ups
TRUE
0
Int16
3-95
Ramp Delay
ExpressionLimit
All set-ups
TRUE
-3
TimD
Parameter Lists
VLT
®
AQUA Drive FC 202
254
Danfoss A/S © 05/2018 All rights reserved.
MG20OB02
4
4
Содержание VLT AQUA Drive FC 202
Страница 2: ......