ESIE13-03
|
Part 3. Repair
2. Unit specific repair procedures
13/05/15
|
Version 2.0
Page 105
Ground source heat pump
2.2.7. Replacing the brine pump
2.2.7.1 Preliminary actions
1. Switch off the Daikin Altherma GSHP via the user interface.
2. Remove the front panel, refer to
"Removing the front panel" on page 85
3. Remove the switch box cover, refer to
"Removing the switch box cover" on page 89
.
4. Open the Sound Insulation of the heat pump module (front side only),
"Opening the sound insulation of the heat pump module
5. Drain the brine circuit, refer to
"Draining the brine circuit" on page 86
2.2.7.2 Procedure
Removal
1. Unplug the connector X77A (5) from the A9P PCB (2).
2. Unplug the 2 Faston connectors from brine pump relay K6M terminals 3-4 (4).
3. Loosen and remove the screw (1) that fixes the brine pump ground wire (3) to the chassis.
4. Guide the brine pump wire (6) through the grommet at the bottom of the switch box.
5. Loosen the nuts (7) that fix the brine pump.
6. Remove the brine pump (8).
7. Remove the seals (9) from the nuts (7).