LED Indicator Groups
Depending on the user application, most of the LED indicator functions are
accessible remotely via SNMP (Simple Network Management Protocol).
“crs500SlotStatusTable” contains the Unit/Tx/Rx status indicator array. See
Section 9.3 SNMP Interface for information about using this Ethernet-based
remote product management protocol.
Figure 8-3. CRS-500 CSU Front Panel – LED Groups
The front panel LEDs (
Figure 8-3
) provide Switch Status, Traffic Modem Status, and Redundant
Modem Status at a glance.
8.1.3.1
Switch Status LED Group
Shown as
Feature 3
in
Figure 8-1, these four LEDs convey the operating state of the CRS-500
System:
SWITCH STATUS
•
Lights GREEN when the system is operating normally (i.e., there are no Switch Faults)
•
Lights RED when there is a Switch Fault (e.g., PSU Fault or COMMS Failure)
MANUAL MODE
•
Flashes ORANGE when the system is in MANUAL mode.
•
Remains OFF when the system is in AUTO Mode.
STORED EVENT
•
Lights GREEN where there are events stored in the Event Log.
•
Remains OFF when there are no events stored in the Event Log (i.e., the log is
clear
).
REMOTE
•
Lights ORANGE when the Switch is in
Remote Mode
. Local monitoring is possible, but
configuration changes through the front panel keypad are disabled.
•
Remains OFF when the Switch is in
Local Mode
. Remote monitoring is possible, but
configuration changes are possible only through the front panel keypad. Remote
configuration is disabled.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...