CRS-500 1:N Redundancy System
Revision 4
Serial Interface Operation
10–14
MN-CRS-500
Parameter
Type
Controller-to-Target
Instruction Code and Qualifier Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Target-to-Controller
Command
Query
Response to
Command
Response to Query
(see Description of
Arguments)
Local/Remote
Status
LRS=
LRS?
1 byte
Command or Query.
Sets or returns the local/remote status of the Switch in the form x, where:
0 = Local (CSU Front Panel)
1 = Ethernet
2 = Ethernet
LRS=
LRS?
LRS=x
MAC Address N/A
MAC?
12 bytes
Query only.
Returns the unique MAC Address for the Switch.
QUERY RESPONSE EXAMPLE: >0000/MAC = 0006B00001CA{CR}{LF}
N/A
MAC=aabbccddeeff
SNMP Read
Community
SRC=
SRC?
Up to 20 bytes Command or Query.
Sets or returns the SNMP Read Community string.
NOTES:
Empty string is not allowed.
20 characters maximum are permitted.
Reboot is required in order for changes to the Read Community string to take
effect.
COMMAND EXAMPLE: <0000/SRC=public{CR}
SRC =
SRC!
SRC=x…x
SNMP Write
Community
SWC=
SWC?
Up to 20 bytes Command or Query.
Sets or returns the SNMP Write Community string.
NOTES:
Empty string is not allowed.
20 characters maximum are permitted.
Reboot is required in order for changes to the Write Community string to take
effect.
COMMAND EXAMPLE: <0000/SWC=private{CR}
SWC =
SWC!
SWC=x…x
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...