CRS-500 1:N Redundancy System
Revision 4
Configure Modems for 1:N Redundancy
7–4
MN-CRS-500
7.4
Configure Modem Operation
Refer to your applicable modem’s Installation and Operation Manual to configure each Traffic
Modem for the proper Rx and Tx IF, power settings, modulation, code rates, and traffic data
settings.
7.5
Configure Modems for 1:N Redundancy
UNLESS OTHERWISE NOTED: Make sure to complete the procedures outlined
in this section for each modem that is installed within the CRS-500 1:N
Redundancy System.
To ensure proper 1:N Redundancy operations, it is important that you not only
refer to the sections that follow, but to also refer to your applicable modem’s
Installation and Operation Manual for detailed information.
7.5.1
Configure CDM-625/A Advanced Satellite Modems
1. Do these steps for each CDM-625/A Advanced Satellite Modem:
a. Enable 1:N Mode for each modem – from each modem front panel:
SELECT: Utility
Redundancy
1:N
(Set to
Enabled
)
b. Assign a unique Management IP Address to each modem – from each modem
front panel:
SELECT: Configuration
IP
Address
Add/Range
(Set address)
c. (Router Mode only) Assign a unique Redundancy Traffic IP Address to each
modem – from each modem front panel:
SELECT: Utility
Redundancy
Traffic-IP-Addr/Range
(Set address)
The Redundancy Traffic IP Address parameter is only applicable
to CDM-625/A systems where the optional IP Packet Processor is
installed and enabled, and where the working mode is set to one
of the router modes.
d. Set the Dedicated Management Port to Port 1 – from each modem front panel:
SELECT: Configuration
IP
Setup
DDMgmtPt
Dedicated Mgmt
Port
Dedicated Management Port Mode is only configurable when the
optional IP Packet Processor is either not installed or is installed
but disabled.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...