CRS-500 1:N Redundancy System
Revision 4
Ethernet Interface Operation
9–14
MN-CRS-500
Traffic Modem Configuration
or
Redundant Modem
Configuration
1. With 1:N set as the default Capacity, Traffic Modems 1 through 10 are
available, while RMI #1 is the default Redundant Modem.
2. For the descriptions that follow: A “status column” provides read-only
information. A “configuration column” requires user input/action. Make
sure to click [Apply changes] after making any changes.
•
The “
Slot#
” and “
RMI#
” status columns identify the chassis slot position.
•
The “
TMI Status
” status column “Virtual LED” lights
GREEN
to indicate the physical
presence of a TMI or RMI in that designated DSU slot. The LED remains
dark
if the DSU
slot is empty.
•
Use the button in the “
Active
” configuration column to toggle the Traffic Modem assigned
to that slot as
[Active]
or
[Inactive]
. Click
[Apply changes]
to save.
RMIs, by default, are always [ACTIVE].
•
The “
Switch IP/Subne
t” status column is non-functional at this time.
•
Typical for any Traffic Modem or the Redundant Modem, type in the IP Address of the
modem into the “Modem IP Address” configuration column for that specific
Slot #
. Click
[Apply changes]
to save.
•
Enter login permissions for each modem in the “
Modem Credentials
Username/Password
” configuration column. These credentials are needed to access
the modem’s HTTP Interface. Click
[Apply changes]
to save.
•
Use the “
Comms
” status column to monitor the status of communications for the
designated DSU slot. The “Virtual LED” lights
GREEN
when communications are active.
The LED lights
RED
when a communications fault is detected.
•
The “
TMI Type
” and “
RMI Type
” status columns identify (by its model number) the
Comtech EF Data module that is installed in that designated slot. For example, “CRS-
520” specifies that a CRS-520 10/100 Ethernet TMI is present.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...