CRS-500 1:N Redundancy System
Revision 4
Cables and Connections
5–10
MN-CRS-500
5.3.1.3
CRS-500
CDM-625/625A 10/100 Ethernet System
Communication Cable Connections
1) The Redundant Modem 10/100 Ethernet port labeled “1” is always connected
to the installed CRS-510 RMI 10/100 Ethernet port labeled “Port 1.”
2) The CRS-520 TMI 10/100 Ethernet port labeled “Port 1” is always connected
to its respective Traffic Modem 10/100 Ethernet port labeled “1”.
3) Modem 10/100 Ethernet ports “2” through “4” are reserved for use as 10/100
Ethernet traffic data connections.
For 1:N connections between the CRS-500 CSU and CDM-625/625A Modems:
The CRS-500 uses 10/100 Ethernet to communicate to all modems. It also uses 10/100 Ethernet
for “pass-through” communications from the user and to/from the modems (including 10/100
Ethernet and Serial M&C).
Never directly connect to any modem for 10/100 Ethernet or Serial M&C. To access any modem
in the redundancy system, connect to the CRS-500 CSU via the CRS-530 System Controller
Ethernet (“10/100 M&C” port) or Serial (“P1 | Remote Control” port) interface.
See
Figure 5-4
. Do these steps:
1. For the Redundant Modem, connect a PP/CAT5FF7FTGY cable between the Redundant
Modem and the CRS-510 RMI:
a. RJ-45 10/100 Ethernet port labeled “1” on the modem, to
b. RJ-45 10/100 Ethernet port labeled “Port 1” on the CRS-510 RMI.
2. For each Traffic Modem, 10/100 Ethernet System Communication is achieved via the
TMI/Traffic Modem route. Connect a PP/CAT5FF7FTGY cable between each Traffic
Modem and its corresponding CRS-520 TMI:
a. RJ-45 10/100 Ethernet port labeled “Port 1” on the CRS-520 TMI, to
b. RJ-45 10/100 Ethernet port labeled “1” on the modem.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...