CRS-500 1:N Redundancy System
Revision 4
Cables and Connections
5–24
MN-CRS-500
5.3.2.4
CRS-500
CDM-750/760 Traffic Data Cable Connections
5.3.2.4.1
10/100/1000 Gigabit Ethernet (GbE) Traffic Data Cable
Connections
1.
Make sure that the modem
CONFIG: REMOTE CONTROL > Inband
(Inband Modem
Control) is disabled.
2.
The Redundant Modem
DSU RMI and DSU TMI
Traffic Modem CA-0000069 control
cable connections should have already been made, as directed in
Section 5.3.2.2
.
3.
The Redundant Modem
DSU RMI and DSU TMI
Traffic Modem PP/CAT5FF7FTGY
Ethernet Comm cable connections should have already been made, as directed in
Section 5.3.2.3.1
.
4.
The Redundant Modem RJ-45 port labeled “J4 | MGMT” is always connected to the
installed CRS-505 RMI Ethernet port labeled “Port 1.” Do not use the “J4 | MGMT” port
for any GbE traffic data connections.
5.
Modem RJ-45 ports labeled “J5 | DATA” and “J6 | DATA” are intended for use as the
GbE traffic data connections.
See Figure 5-10. Do these steps:
1.
For the Redundant Modem, connect PP/CAT5FF7FTGY cable(s) between the
Redundant Modem and the CRS-505 RMI:
a.
Redundant Modem RJ-45 port labeled “J5 |DATA” or “J6 | DATA” to
b.
CRS-505 RMI RJ-45 port labeled “Port 2” through “Port 4”.
2.
For each Traffic Modem, connect PP/CAT5FF7FTGY cable(s) between each CRS-516
TMI and its respective Traffic Modem:
a.
CRS-516 TMI RJ-45 port labeled “Port 2” through “Port 4” to
b.
Traffic Modem RJ-45 port labeled “J5 |DATA” or “J6 | DATA”.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...