CRS-500 1:N Redundancy System
Revision 4
CSU Front Panel Operation
8–16
MN-CRS-500
8.2.2.5.3
CONFIG:
Options→Alarm-Mask
Alarm Mask: Modem-Alarms
Switch-Alarms Audio
The Switch logs and reacts to both its own faults and modem faults. Use this submenu to mask
either type of faults. In addition, an audible buzzer can be enabled as an additional indicator.
Use the
◄ ► arrow keys to select
Modem-Alarms
,
Switch-Alarms
, or
Audio
. Press
ENTER
.
C
ONFIG: Options→Alarm
-
Mask→Modem
-
Alarms
This menu operation is global for all modems in the system. Should you desire to
mask individual modem faults, you should do so directly from that modem’s front
panel. Unmasked modem faults are logged on active modems only.
Modem Alarm Mask:
None Tx Rx Tx+Rx
Use the ◄ ► arrow keys to select
None
,
Tx, Rx, or Tx+Rx
. Press
ENTER
.
You may select
Tx
to mask Transmit Traffic Faults,
Rx
to mask Receive Traffic faults, or
Tx+Rx
to mask both Traffic and Receive Faults from being reacted to by the Switch. This not only
prevents the Switch from performing Auto Mode functions when these modem faults are sensed,
but also keeps the faults from being logged by the Switch.
C
ONFIG: Options→Alarm
-
Mask→ Switch
-
Alarms
Switch Alarm Mask: None
PSU-A PSU-B
Select a plug-in power supply unit to mask. You may mask only one unit at a time. You would
normally mask a PSU if you choose to run with only one PSU, or if you need to remove a bad
PSU for service or replacement.
Use the ◄ ► arrow keys to select
None
,
PSU-A
or
PSU-B
. Press
ENTER
.
C
ONFIG: Options
→ Alarm
-
Mask → Audio
Audio Mask: None Sw-Alm
Modem-Alarms All
For all unmasked Switch or modem alarms, you may select which alarm types should force the
Switch to react with an audible buzzer (located behind the CSU front panel). In addition, a relay
closure to ground activates on Pin 20 of the “J1 | System Alarms” DB-25F connector (located on
the CRS-530 System Controller module) so that you may attach other indicators.
Use the
◄ ► arrow keys to select
None
,
Sw-Alm
,
Modem-Alarms
, or
All
. Press
ENTER
.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...