CRS-500 1:N Redundancy System
Revision 4
Cables and Connections
5–9
MN-CRS-500
Figure 5-3 shows the 10/100 Ethernet ports (labeled “1” through “4”) on the CDM-625/625A rear
panel.
1) When using the CRS-316 TMI, a PP/CAT5FF7FTGY cable (CAT5 RJ-45 to RJ-
45, 7’) is required for Ethernet management between each modem and the
CRS-512 Ethernet M&C Interface installed in the CSU rear panel.
2) Use Port 1 only for the CRS-500 Ethernet System Communication connection
between the CRS-500 and the CDM-625/625A modems.
3) Avoid Ethernet Networking loops. When CDM-625s are operating in IP Packet
Processor Router or Managed Switch Mode, use only a single port to convey
traffic data for each modem.
Figure 5-3. CDM-625/625A 10/100 Ethernet Ports
Figure 5-3 Notes:
1) Use Port 1 for CRS-500-to-CDM-625/625A Ethernet System Communications.
2) Use any single port (Port 2, 3, or 4) for CDM-625/625A Ethernet traffic data connection.
5.3.1.2
CRS-500
CDM-625/625A Control Cable Connections
For 1:N connections between the CRS-500 CSU to CDM-625/625A Modems:
The CA/WR0066 Control Cable (DB-25M to DB-25F, 6’) or CA-0000069 Control Cable (HD-15M
to DB-9M, 6’) provide the modem’s fault status information to the CRS-500 as well as the control
path to the modem’s external Tx IF-mute (for the offline modem). Therefore, it is always required.
See
Figure 5-4
. Do these steps:
1. For the Redundant Modem, connect the CA/WR0066 Control Cable between the
Redundant Modem and its corresponding RMI:
a. DB-25F connector labeled “Data Interface” on the modem, to
b. DB-25M connector labeled “P1” on the RMI.
2. For each Traffic Modem, connect a CA-0000069 Control Cable between each TMI and its
corresponding Traffic Modem:
a. HD-15F connector labeled “Faults” on the TMI, to
b. DB-9F connector labeled “1:1 Control” on the modem.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...