CRS-500 1:N Redundancy System
Revision 4
Serial Interface Operation
10–1
MN-CRS-500
Chapter 10. SERIAL INTERFACE OPERATION
10.1 Overview
See Section B.3.1.1 in Appendix B. CONTROLLER / TMI CONNECTORS AND PINOUTS for the EIA-232/485 Interface
connector pinout table.
Serial remote product management of Comtech EF Data’s CRS-500 1:N Redundancy System is available using the ‘
P1 | Remote
Control
’ DB-9M port located on the CSU rear panel CRS-530 System Controller Module. This chapter summarizes key parameters and
procedures and their associated remote commands and queries, and provides detailed instructions for use of the serial remote interface.
Before you proceed with serial remote product management, make sure the following is true:
•
Your CRS-500 and its Redundant and Traffic Modems are interconnected and are operating with the latest
version firmware files.
•
You are using a Windows-based PC (user-provided) that is connected to the CRS-500 as follows:
o
The User PC serial port is connected with a user-supplied serial cable to the ‘P1 | Remote Control’ DB-9M
port located on the CSU rear panel CRS-530 System Controller Module.
o
The User PC Ethernet port is connected via a user-supplied hub, switch, or direct Ethernet CAT5 cable
connection to the CRS-500.
o
The User PC is running a terminal emulation program (for operation of the CRS-500 Serial or Telnet
Interface) and a compatible Web browser (for operation of the CRS-500 HTTP (Web Server) Interface).
o
The CRS-5000 Management IP Address has been noted using the CRS-500 Serial Interface or HTTP Interface.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...