10.3.1 Redundancy Commands and Queries
Parameter
Type
Controller-to-Target
Instruction Code and Qualifier Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Target-to-Controller
Command
Query
Response to
Command
Response to Query
(see Description of
Arguments)
Audio Alarm
Mask
AAM=
AAM?
1 byte
Command or Query.
Sets or returns the audio alarm mask in the form x, where:
0 = No faults masked (audio enabled in response to any fault)
1 = Switch faults masked
2 = Modem faults masked
3 = All faults masked (audio never enabled)
AAM=
AAM?
AAM*
AAM=x
Configure
Active
Modems
ACT=
ACT?
10 bytes
Command or Query.
Sets or returns the active state of all 10 Traffic Modems in the form xxxxxxxxxx,
where:
0 = de-activate Traffic Modem (except if in backup)
1 = activate Traffic Modem
NOTE: Redundant modems are always active.
ACT=
ACT?
ACT*
ACT=xxxxxxxxxx
Active Modem
Status
N/A
AMQ?
10 bytes
Query only.
Returns the state of all 10 Traffic Modems in the form xxxxxxxxxx, where:
0 = TMI not present. Modem cannot be activated.
1 = TMI present, but modem not activated.
2 = TMI present, modem activated and responding.
3 = TMI present, modem activated but not responding.
N/A
AMQ=xxxxxxxxxx
Bridged or
Backed-up
Modem
Number
(Redundant
Modem 1)
BB1=
BB1?
3 byte
Command or Query.
Sets or returns the bridge/backup state for RM1, followed by the selected TM to
be acted on, in the form xyy where:
x = 0 or 1, where 0 = RM1 to Bridge; 1 = RM1 to Back Up (valid only in Manual
Switching Mode)
yy = TM 01 through 10 (modem number in 1:N mode)
BB1=
BB1?
BB1*
BB1=xyy
Backup
Holdoff Time
BKH=
BKH?
2 bytes
Command or Query.
Sets or returns the backup holdoff time, in seconds, in the form xx, where:
xx = 01 through 99
NOTE: This is the number of seconds in time delay that Auto Mode inserts,
before online swap actually takes place, after Redundant Modem 1 has acquired
the faulted Traffic Modem’s configuration.
BKH=
BKH?
BKH*
BKH=xx
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...