CRS-500 1:N Redundancy System
Revision 4
Serial Interface Operation
10–15
MN-CRS-500
10.3.3 Unit Information Commands and Queries
Parameter
Type
Controller-to-Target
Instruction Code and Qualifier Arguments for
Command or
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e.,
ASCII codes between 48 and 57)
Target-to-Controller
Command
Query
Response to
Command
Response to Query
(see Description of
Arguments)
Faults and
Status
N/A
FLT?
12 bytes
Query only.
Unit returns the current fault and status codes for the Switch itself in the form
xyABCDEFGmit, where:
x = RM1 status (0, 1, 2, 4) where:
0=OK
1=RM not present
2=RM comm loss
4=RM rejecting configuration string
y= RM2 status (reserved for future use; RM2 is not supported yet, so this will
always be '*')
A = +3.3v power supply (where 0 = OK, 1 = FAULT)
B = +2.5v power supply (where 0 = OK, 1 = FAULT)
C = +5v power supply (where 0 = OK, 1 = FAULT)
D = +12v power supply module “A” (where 0 = OK, 1 = FAULT)
E = +12v power supply module “B” (where 0 = OK, 1 = FAULT)
F = -12v power supply module “A” (where 0 = OK, 1 = FAULT)
G = -12v power supply module “B” (where 0 = OK, 1 = FAULT)
m = Position of TMI with mismatched data type (where 0 = OK, 1..A = FAULT)
i = Position of TMI with comm loss (where 0 = OK, 1..A = FAULT)
t = Temperature fault (where 0 = OK, 1 = FAULT)
NOTES:
1)
It is possible to get the fault status of each CDM-625/A by querying the CDM-
625/A itself through the unit-addressable remote strings (see the CDM-625/A
manuals for the CDM-625/A FLT query description).
2)
The CRS-500 ties up the Telnet connection on each CDM-625/A, so it is
necessary to execute these queries through the CRS-500 remote control
interface (Serial or Telnet). For example:
<0000/FLT?{CR} = Fault status of CRS-500 controller
<0100/FLT?{CR} = Fault status of TM1
<0200/FLT?{CR} = Fault status of TM2
<1000/FLT?{CR} = Fault status of TM10
<1100/FLT?{CR} = Fault status of RM1
N/A
FLT=xABCDEFGmit
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...