CRS-500 1:N Redundancy System
Revision 4
Cables and Connections
5–26
MN-CRS-500
5.3.2.4.2
Unbalanced G.703 Traffic Data Cable Connections
1.
G.703 Unbalanced traffic is possible only when the modem is equipped with the optional
G.703 Plug-In Interface Cards (PIIC). This traffic data type requires use of the CRS-345
TMI.
2.
The Redundant Modem
DSU RMI and DSU TMI
Traffic Modem CA-0000069 control
cable connections should have already been made, as directed in
Section 5.3.2.2
.
3.
The Redundant Modem
CSU CRS-512 and DSU TMI
Traffic Modem
PP/CAT5FF7FTGY Ethernet Comm cable connections should have already been made,
as directed in
Section 5.3.2.3.2
.
See Figure 5-11. Do these steps:
1.
For the Redundant Modem, connect the CA-0000750 Cable (4X BNC to DB-9F, 6’)
between the Redundant Modem G.703 PIIC and the CRS-505 RMI:
a.
First, connect cable BNC connector ‘1’ to the PIIC “RX-OUT” port, and cable
BNC Connector ‘2’ to the PIIC “TX-IN” port; then, connect to
b.
CRS-505 RMI DB-9M connector labeled “P1 | G.703/ASI”.
2.
For each Traffic Modem, connect the CA-0000703 Cable (4X BNC to DB-9F, 6’) between
each CRS-345 TMI and its respective Traffic Modem PIIC:
a.
For single module connections (see Figure 5-11 for TMs 2 and 4):
•
CRS-516 TMI DB-9M port labeled “P1 | BNC Adapter” to
•
(Slot 1 PIIC) Cable BNC Connector ‘1’ to the PIIC “RX-OUT” port, and cable
BNC Connector ‘2’ to the PIIC “TX-IN” port.
b.
For dual module connections (see Figure 5-11 for TM 6):
•
CRS-516 TMI DB-9M port labeled “P1 | BNC Adapter” to
•
(Slot 1 PIIC) cable BNC Connector ‘1’ to the PIIC “RX-OUT” port, and cable
BNC Connector ‘2’ to the PIIC “TX-IN” port, and
•
(Slot 2 PIIC) cable BNC Connector ‘3’ to the PIIC “RX-OUT” port, and cable
BNC Connector ‘4’ to the PIIC “TX-IN” port.
Содержание CRS-500
Страница 24: ...CRS 500 1 N Redundancy System Revision 4 Preface x MN CRS 500 Notes...
Страница 38: ...CRS 500 1 N Redundancy System Revision 4 Introduction 1 14 MN CRS 500 BLANK PAGE...
Страница 54: ...CRS 500 1 N Redundancy System Revision 4 Checklists for Initial Start up and Configuration 3 6 MN CRS 500 Notes...
Страница 60: ...CRS 500 1 N Redundancy System Revision 4 Installation 4 6 MN CRS 500 BLANK PAGE...
Страница 164: ...CRS 500 1 N Redundancy System Revision 4 Ethernet Interface Operation 9 22 MN CRS 500 BLANK PAGE...
Страница 184: ...CRS 500 1 N Redundancy System Revision 4 Serial Interface Operation 10 20 MN CRS 500 BLANK PAGE...
Страница 216: ...CRS 500 1 N Redundancy System Revision 4 Appendix C C 4 MN CRS 500 Figure C 2 External EIA 485 with CDM 625 A Modems...
Страница 219: ......
Страница 220: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...