60
Indicates that during a cycle, there was a drop in the
power supply to the unit. When power is restored to the
unit, the display will show a message about the phase in
which power dropped.
Whenever there is a power cut while an alarm is active,
the display will show the last alarm triggered.
Indicates that a time-controlled phase (sterilization, drying
or maintenance in the Vacuum Test) was not correctly
completed.
•
Contact a technical service center.
•
Check the power supply at the plug, and that the
power cord 03
is inserted correctly in the plug and
in its connection in the sterilizer.
•
Check the
fuses 32
and that the
main switch 13
is
pressed to the “I” position.
•
Check the efficiency and cleanliness of the
door
gasket 31
as well as the
door 16
disk the seal is
fitted to. Replace if damaged (see Ch.
MAINTENANCE).
•
Contact a technical service center to have the
door 16
closure adjusted.
At the end of the cycle, there is still water in the
chamber
09.
•
Check that the
drain
filter 20
is clean and
positioned correctly (see Ch. MAINTENANCE).
•
Recheck the tilt of the sterilizer (see Ch.
INSTALLATION).
Drying after the cycle is not satisfactory.
•
Check that the cycle selected is appropriate for
the material to be sterilized (see Table of
cycles/sterilizable material).
•
Check that the total maximum load weight has not
been exceeded (see Table of cycles/sterilizable
material).
•
Check that the load was correctly prepared.
•
Check the
air sterilization filter 15
and replace if
needed (see Ch. MAINTENANCE).
•
Follow the instructions provided for the previous
problem.
At the end of the cycle, pressure rises very slowly.
•
Check the
air sterilization filter 15
and replace if
needed (see Ch. MAINTENANCE).
The
printer 26
(optional, standard on PRINT models) does
not print.
•
Check that the printer has been enabled in the
Main Settings Menu (see Ch. OPERATION).
POWER MISSING
ALARM
PRINTER
DOES NOT PRINT
STEAM LOSS
FROM THE DOOR
WATER IN THE
CHAMBER AFTER
THE CYCLE
DRYING
UNSATISFACTORY
PRESSURE
INCREASES SLOWLY
NO MESSAGE IS
SHOWN ON THE
DISPLAY
EVENTS
ALARM
Alarms
Содержание SterilClave 18 VLS
Страница 2: ...2...
Страница 7: ...7 Graphic representation of references Mod 18 Table of contents...
Страница 8: ...8 Graphic representation of references Mod 24 Table of contents...
Страница 9: ...9 06 06A OPTIONAL OPTIONAL Table of contents...
Страница 10: ...10...
Страница 70: ...70...
Страница 71: ...71...