7-11
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1
OL-24002-01
Chapter 7 Installing the IPS 4510 and IPS 4520
Memory Configurations
Memory Configurations
The IPS 4510 and IPS 4520 have up to 6 DIMM modules per CPU. DIMM population is
platform-dependent.
Table 7-5
shows the memory configurations.
Power Supply Module Requirements
Table 7-6
lists the power supply module requirements.
Note
The IPS 4520 requires two power supply modules.
Supported SFP/SFP+ Modules
The SFP/SFP+ module is a hot-swappable input/output device that plugs into the SFP/SFP+ ports and
provides Gigabit Ethernet connectivity. The SFP and SFP+ modules are optional and not included with
the IPS 4510 and IPS 4520. You can purchase them separately. For 1 Gb, you need SFP. For 10Gb, you
need SFP+. The interfaces are called TenGigabitEthernet 0/
x
whether they are 10 Gb-enabled or not.
Table 7-5
Memory Configurations
Model
Memory
IPS 4510
24-GB DRAM
IPS 4520
48-GB DRAM
Table 7-6
Power Supply Module Requirements
50 V
12 V
3.3 V_STBY
Output Voltage
Maximum
52.0 V
12.2. V
3.45 V
Nominal
50.0 V
12.0 V
3.35 V
Minimum
48.0 V
11.8 V
3.25 V
Output Current @ 200 VAC
Maximum
17.3 A
27.0 A
1.5 A
Minimum
0
0
0
Output Current @ 100 VAC
Maximum
17.3 A
27.0 A
1.5 A
Minimum
0
0
0