7-10
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1
OL-24002-01
Chapter 7 Installing the IPS 4510 and IPS 4520
Accessories
Accessories
The contents of the sensor packing box contains the following items you need to install the sensor:
•
Sensor chassis
•
Documentation
•
2 Yellow Ethernet cables
•
Blue console cable PC terminal adapter
•
Power cable 120V
Note
The IPS 4510 ships with one power supply module installed and one power cable. The IPS
4520, ships with two power supply modules installed and two power cables.
•
Screws
•
Cable management brackets
•
Front and rear rack-mount brackets
•
Slide rail kit hardware
•
Slide rail kit
Maximum heat dissipation
3960 BTU/hr (100 VAC)
5450 BTU/hr (200 VAC)
Power supply output steady state
Maximum peak
1200W
1200W
Environment
Temperature
Operating 32°F to 104°F (0°C to 40°C)
Nonoperating -40°F to 158°F (-40°C to 70°C)
Airflow
Front to back
Relative humidity
(noncondensing)
Operating 10% to 90%
Nonoperating 5% to 95%
Altitude
Operating 0 to 3000 ft (9843 ft)
Nonoperating 0 to 4570 ft (15,000 ft)
Shock
Operating Half-sine 2 G, 11 ms pulse, 100 pulses
Nonoperating 15 G, 170 in/sec delta V
Vibration
2.2 Grms, 10 minutes per axis on all three axes
Noise
65 dBa max
Table 7-4
IPS 4510 and IPS 4520 Specifications (continued)