5-50
Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1
OL-24002-01
Chapter 5 Installing the IPS 4270-20
Installing and Removing Fans
Installing and Removing Fans
There are six fans in the IPS 4270-20. The IPS 4270-20 supports redundant hot-pluggable fans in a 5 + 1
configuration to provide proper airflow.
Figure 5-12
shows the fan, its connector, and its indicator.
Figure 5-12
Fan, Connector, and Indicator
The fan indicators provide the following information:
•
Green—Operating normally
•
Amber—Failed
•
Off— No power
To install and remove fans in the IPS 4270-20, follow these steps:
Step 1
Extend the server from the rack.
Step 2
Remove the chassis cover.
Step 3
Identify the failed fan by locating an amber indicator on top of the failed fan or a lighted FAN X indicator
on the Diagnostic Panel.