Appendix G. CRBasic Program Library
G-3
'Low Frequency Boundary (sensor frequency should never fall below
'this value regardless of environmental changes)
Dim
F_Low(8)
=
{ 300, 300, 300, 300, 300, 300, 300, 300}
'High Frequency Boundary (sensor frequency should never exceed
'this value regardless of environmental changes)
Dim
F_High(8)
=
{ 6000, 6000, 6000, 6000, 6000, 6000, 6000, 6000}
'Output Format - Hz vs. Hz^2 :: Value of 0 – measured frequency is given in units of Hz,
'Value of 1 – measured frequency is squared and given in units of Hz^2
Dim
OutForm(8)
As Long
=
{ 0, 0, 0, 0, 0, 0, 0, 0}
'Multiplier (factor) to be applied to sensor output frequency
Dim
Mult(8)
=
{ 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0}
'Offset (shift) to be applied to sensor output frequency
Dim
Off(8)
=
{ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
'Steinhart-Hart coefficients [A,B,C] for converting thermistor ohms to
'temperature in Celsius. Specifying zeroes for A,B,C results in a reading in Ohms.
Dim
SteinA(8)
=
{ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
Dim
SteinB(8)
=
{ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
Dim
SteinC(8)
=
{ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0}
'Rainflow configuration (not used in this program, but required as configuration arguments)
Dim
RFMB(8)
As Long
=
{ 20, 20, 20, 20, 20, 20, 20, 20}
Dim
RFAB(8)
As Long
=
{ 20, 20, 20, 20, 20, 20, 20, 20}
Dim
RFLL(8)
=
{ 400.0, 400.0, 400.0, 400.0, 400.0, 400.0, 400.0, 400.0}
Dim
RFHL(8)
=
{4000.0,4000.0,4000.0,4000.0,4000.0,4000.0,4000.0,4000.0}
Dim
RFHY(8)
=
{ 0.005, 0.005, 0.005, 0.005, 0.005, 0.005, 0.005, 0.005}
Dim
RFOF(8)
As Long
=
{ 100, 100, 100, 100, 100, 100, 100, 100}
'Configure the CDM-VW300 series device. Use the variable arrays declared above.
CDM_VW300Config
(1,CPI_ADDR,0,Enable(),Max_AMP(),F_Low(),F_High(), _
OutForm(),Mult(),Off(), SteinA(),SteinB(),SteinC(), _
RFMB(),RFAB(),RFLL(),RFHL(),RFHY(),RFOF())
DataTable
(static,true,-1)
'Static Frequency reading (1Hz output)
Sample
(8,StaticFreq(),IEEE4)
'Thermistor reading : Ohms or DegC
Sample
(8,Therm(),IEEE4)
'Standard Deviation of dynamic readings taken during the most recent second
Sample
(8,DynStdDev(),IEEE4)
EndTable
DataTable
(dynamic,true,-1)
'Dynamic Frequency (20Hz output)
Sample
(8,Freq(),IEEE4)
'Diagnostic code for the current dynamic reading
Sample
(8,Diag(),IEEE4)
EndTable
BeginProg
'20 Hz/50msec scan rate
Scan
(50,msec,500,0)
CDM_VW300Dynamic
(CPI_ADDR,Freq(),Diag())
'Get dynamic readings
CallTable
dynamic
If TimeIntoInterval
(0,1,Sec)
Then
'Process static data only once per second
CDM_VW300Static
(CPI_ADDR,StaticFreq(),Therm(),DynStdDev())
'Get static readings
CallTable
static
EndIf
NextScan
EndProg
G.1.3 20 Hz Measurement Example
— Three CDM-VW305s, 24
Channels
'===20Hz-3Devices8Ch_3-25-13.CR3===
'CR3000 datalogger
'CDM-VW305 vibrating-wire analyzer
'Program to read 20-Hz dynamic data from three CDM-VW305 analyzers (8x3=24 channels)
'IMPORTANT -- Ensure that the CPI addresses coded on the following lines matches the addresses
'reported for each attached analyzer in the DevConfig or DVWTool software.
Const
CPI_ADDR1
=
5
Const
CPI_ADDR2
=
15
Const
CPI_ADDR3
=
25
Public
Freq1(8), Freq2(8), Freq3(8)
'dynamic frequencies
Public
Diag1(8)
As Long
, Diag2(8)
As Long
, Diag3(8)
As Long
'diagnostic codes
Public
StaticFreq1(8), StaticFreq2(8), StaticFreq3(8)
'Static (1Hz output) frequencies
Содержание CDM-VW300 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 12: ......
Страница 59: ...User Manual 47 Figure 7 16 LoggerNet connect screens showing frequencies from CDM VW300 ...
Страница 70: ...CDM VW300 Series Dynamic Vibrating Wire Analyzers 58 ...
Страница 76: ...Appendix B SC CPI Datalogger to CPI Interface B 4 ...
Страница 80: ...Appendix C CDM Devices and CPI Bus C 4 Figure C 2 Long cable lengths of a distributed CPI bus ...
Страница 82: ...Appendix D Digits Conversion D 2 Figure D 1 Geokon Calibration Report of a Sensor without a Thermistor ...
Страница 86: ...Appendix E Calculating Measurement Error E 4 ...
Страница 116: ...Appendix G CRBasic Program Library G 26 ...
Страница 117: ...Appendix G CRBasic Program Library G 27 ...