73
SmartStack SSIM-A2-01/SSIM-A8-01
0504 CRC checksum failure on adapter Eeprom.
This message indicates a hardware error with the ATM Uplink.
Action: Replace ATM Uplink card.
0505 SAR memory self-test failed during open.
This message indicates a hardware error with the ATM Uplink.
Action: Replace ATM Uplink card.
0601 Registered Prefix did not match configuration.
A Prefix registered by switch could not be matched to the ATM address of any
configured Elan. This does not necessarily indicate a problem.
Action: Check Elan configuration against switch configuration.
0602 Configured Prefix remained unregistered after time-out.
The ATM address of one or more configured Elan’s was not registered before the
ATM Uplink open timed out. Open of (one of) the affected Elan(s) will fail with
Completion Code: CC_LME_ADDR_NOT_REG (0x6D).
Action: Check Elan configuration against switch configuration.
0603 Configured Prefix overridden by registered Prefix,
Elan
No: <xx>
For the present driver version the first registered Prefix is used for all configured
Elan’s, independently of what Elan ATM address may have been configured. This
is a warning only.
Action: Check that any reference to the address of this LEC or LES in the
configuration files of other stations contains the prefix actually used.
0604 Registration/de-registration of address (SNMP SET)
failed, cc: <xx>.
The address table in the switch could not be updated.
Action: Check for configuration problems such as duplicate ATM address. Check
cabling to switch and that switch is still operative.
0605 Attempt to register the same Elan twice, Elan No: <xx>.
The Operating system has tried to register twice with the same Elan number.
Action: Change the Elan number for one of the Elans, or remove one of the Elans
from the Operating system network configuration.
0703 ILMI: Parsing of SNMP PDU failed, cc = <xx>.
Parsing of a received PDU failed with one of the following cause codes:
2. PDU not SNMP version 1.
4. Illegal or unsupported ASN1 encoding.
5. Out of Workspace memory.
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...