74
SmartStack SSIM-A2-01/SSIM-A8-01
Action: Check compatibility of clients and LAN Emulation services participating
in emulated LAN.
0707 ILMI: Prefix Registration time-out, Cold Start retried.
Time-out of Prefix registration from switch. Address registration procedure is
restarted by re-sending Cold Start trap.
Action: Informative message, see also code 602.
0708 ILMI: Get Response time-out, Get Request retried.
Time-out of switch response to Get Next request. The Get Next request is re-sent.
Action: Informative message, see also code 602.
0709 ILMI: Cold Start Trap received from switch.
Information: The switch has reinitialized the port.
Action: Informative message, the end stations should automatically recover lost
connections.
070A ILMI: MIB access failed: text.
Switch access to the local ILMI MIB failed for one of the following reasons:
Too Big:
Response larger than supported PDU size (448).
BadValue:
Set operation with illegal value.
ReadOnly:
Set operation to read-only variable.
GenErr:
Action: Check compatibility of clients and LAN Emulation services participating
in emulated LAN.
0803 PVC Response only on CDIR-VCC or CD-VCC.
The LAN Emulation Server and the LAN Emulation Client configuration of the
ControlDirect or the ControlDistribute PVC does not match.
Action: Correct the configuration of the ControlDirect or the ControlDistribute
PVC.
0804 PVC Request with multicast only on MD-VCC or MS-VCC.
The LAN Emulation Server and the LAN Emulation Client configuration of the
MulticastSend or MulticastForward PVC does not match.
Action: Correct the configuration of the MulticastSend or MulticastForward PVC.
0805 PVC Request with multicast only sent on MS-VCC.
The LAN Emulation Server and the LAN Emulation Client configuration of the
MulticastSend PVC does not match.
Action: Correct the configuration of the MulticastSend PVC.
0806 A System PVC has been defined twice.
A system PVC (ControlDirect, ControlDistribute, MulticastSend or
MulticastForward) has been defined twice.
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...