24
SmartStack SSIM-A2-01/SSIM-A8-01
Console Configuration
Connection Control Timer (tenths of sec)
Sets the value of the Connection Control Timer variable. As a guideline, set the
value greater than Timer_POLL and round-trip delay.
Possible values: 1 to 255.
Default: 1.
Signal Timing Settings (in seconds)
This section of the screen contains advanced signalling parameters as described
below.
T301
The maximum time to wait for CONNECT after receiving ALERT. The value must
be a minimum of 180 seconds.
Possible values: from 1 to 65,535.
Default: 180.
T303
The maximum time to wait for network response to SETUP.
Possible values: 1 to 255.
Default: 4.
T308
The maximum time to wait for network response to RELEASE.
Possible values: 1 to 255.
Default: 30.
T309
The maximum time allowed for SAAL connection loss.
Possible values: 1 to 255.
Default: 1.
T310
The maximum time to wait for final response after receiving CALL
PROCEEDING.
Possible values: 1 to 255.
Default: 10.
T313
The maximum time to wait for response to CONNECT.
Possible values: 1 to 255.
Default: 4.