Max Line Rate (cells/sec)
Sets the maximum peak rate of the physical link between the module and the ATM
switch. The value set affects all VCCs regardless of their individual traffic profile
settings.
Possible values: from 353 through 353,208.
Default: 353,208 (approximately 150 Megabits per second).
Total # Simultaneous SVC calls in progress
Sets the maximum number of ATM calls in progress. Calls that exceed the limit are
queued (delayed) until they can be processed.
Possible values: 1 to 128.
Default: 128.