70
SmartStack SSIM-A2-01/SSIM-A8-01
0206 Outg. call rejected by network: <Called ATM address>
<Location Code>:<Cause Code>
As for '0204', but where the call is rejected by the 'ATM network', as coded by the
'location' field:
The location code is normally 1, but may also be one of the following:
1
Local Private Network
2
Local Public Network
3
Transit Network
4
Remote Public Network
5
Remote Private Network
7
International Network
10
Beyond International Network
0301 The signalling control link is active
The signalling control link (via the SSCOP protocol) is now active, and the
Signalling protocol is now able to communicate through the switch. If this annuls
a previous loss of the signalling control link (that is, inactive link), the signaling
protocol will at this time check the state of all its active SVCs with its peer in the
ATM switch - if the state of a SVC in both peers are not compatible, the SVC will
be released by the Signalling protocol.
0302 The signalling control link is INACTIVE
The signalling control link (via the SSCOP protocol) is now no longer active, and
the Signalling protocol is now no longer able to communicate through the switch.
This means that currently no more SVCs can be established. Further, the signalling
protocol will release all SVCs currently under establishment.
Note that all SVCs that are already fully established will not be released because of
the inactive link - only if the link is not re-established within a timeout, will the
active SVCs be released by the Signalling protocol.
However, any “Data Direct” SVCs may be cleared by the LAN Emulation protocol
due to inactivity, assuming that data traffic also have ceased.
The inactive signalling control link may be caused by the ATM switch restarting
(or failing), the ATM switch being overloaded, or by a poor physical (cable)
connection.
Action: Check the ATM switch - if it has failed, then restart it - if it is overloaded,
then take steps to reduce its load. Check the physical (cable) connection and fix any
problems.
0401 SSCOP: Receipt of unsolicited or inappropriate <PDU-PDU
Type>
A PDU of type <PDU Type> has been received, which is not expected in the
current protocol context. The <PDU Type> may be one of the following:
SD PDU
BGN PDU
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...