28
SmartStack SSIM-A2-01/SSIM-A8-01
Console Configuration
Max Rx Rate Threshold (cells/sec)
Sets the maximum difference between the requested receive rate of an incoming
LANE call and the line rate, above which the call is rejected with the cause “User
cell rate not available”. Note that the default value of this parameter effectively
disables checking of the requested receive rate. Checking is disabled to ensure
interoperability with equipment that does not handle call rejection with the cause
“User cell rate not available”. To enable checking, set a smaller value (for example
2000 cells/sec).
Possible values: from 0 through 16,777,215 (default).
Max Tx Rate Threshold (cells/sec)
Sets the maximum difference between the requested transmit rate of an incoming
call (the backward rate) and the closest matching traffic profile, above which the
call is rejected with the cause “User cell rate not available”. Note that the default
value of this parameter effectively disables checking of the requested transmit rate.
Checking is disabled to ensure interoperability with equipment that does not handle
call rejection with the cause “User cell rate not available”. To enable checking, set
a smaller value (for example 2000 cells/sec).
Possible values: from 0 through 16,777,215 (default).
Default Traffic Profile
Sets the default traffic profile to use when the VCC being opened has no associated
traffic profile. The default profile can be selected from the list of defined profiles.
Default: HW Default.
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...