12
SmartStack SSIM-A2-01/SSIM-A8-01
Installation
LEDs
There are four LEDs on the front panel of the SSIM-Ax-01 module. The LEDs
show the module status and activity. Table 2 explains the status LEDs on the left of
the module front panel, and Table 3 explains the ATM interface LEDs on the right
of the module front panel.
Table 4 shows the LED status for the SSIM-Ax-01 module under normal operating
conditions.
LED
Position
State
Meaning
DIAG (green)
Top
On
Diagnostics are in progress
Off
No diagnostics are in process
ERR (yellow)
Bottom
On
A module failure has
occurred
Off
The module is working
correctly
Table 2. Status LEDs and their Meanings
LED
Position
State
Meaning
RXSYNC (green)
Top
On
The ATM interface is
receiving a signal
Off
The ATM interface is not
attached to a live transmitter
SIGLOSS
(yellow)
Bottom
On
The ATM receive signal is
below an acceptable level
Off
The ATM receive signal is
acceptable
Table 3. ATM Interface LEDs and their Meanings
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...