46
SmartStack SSIM-A2-01/SSIM-A8-01
Statistics
Invalid Tag
The number of frames in the transmit direction (to ATM) that were dropped due to
an invalid tag.
Dropped Frames
The number of frames dropped due to receive congestion at the beginning of the
frame.
CRC Errors
The number of frames received from the ATM network with CRC errors.
Overflow Errors
The number of frames dropped due to receive congestion after the module has
started receiving the frame.
Bad Channel
The number of frames in the transmit direction (to ATM) that were dropped due to
a bad channel state (the channel selected by the frame tag was not in use).
Unknown VCC
The number of frames received from the ATM network on a VCC that has not been
activated.
Frame too Long
The number of frames received from the ATM network with a length greater than
the maximum length receivable.
Frame too Short
The number of frames received from the ATM network with less than the minimum
data content.
ATM Interface TC Table
Number of times cable has been removed
The number of times the out of cell delineation (OCD) event has occurred. When
seven consecutive ATM cells have header error control (HEA) violations, an OCD
event occurs. A high number of OCD events may indicate a problem with the TC
sublayer.
Cable insertion state
Shows the current cable insertion state.
Содержание SSIM-A2-01
Страница 1: ...SSIM A2 01 SSIM A8 01 ATM 155 SmartStack Interface Modules Installation and User Guide ...
Страница 11: ...2 SmartStack SSIM A2 01 SSIM A8 01 Introduction ...
Страница 49: ...40 SmartStack SSIM A2 01 SSIM A8 01 Console Configuration ...
Страница 71: ...62 SmartStack SSIM A2 01 SSIM A8 01 Getting in Touch with Technical Support ...
Страница 88: ... 710001815 ...