22
SmartStack SSIM-A2-01/SSIM-A8-01
Console Configuration
ATM Network Advanced Parameters
To view and edit advanced network parameters for the ATM network, select
Advanced Parameters on the ATM Network Setup screen.
The following items are available in the SSCOP section of the screen:
SSCOP
Maximum Receive Window Size
Sets the maximum SSCOP protocol receive window size in bytes.
Possible values: 1 to 16,777,215.
Default: 65,536.
Maximum Connection Control States
Sets the maximum number of transmissions of a BGN, END, ER or RS protocol
data unit.
Possible values: 1 to 255.
Default: 4.
Maximum Poll Data States
Sets the maximum number of data packet transmissions between polls.
Possible values: 1 to 255.
Default: 4.